RA LOC SWITCH (5292)    OPTION (19)

View in ViViaN Menu
Name Value
NAME RA LOC SWITCH
X ACTION PRESENT YES
MENU TEXT Switch Locations
UPPERCASE MENU TEXT SWITCH LOCATIONS
PACKAGE RADIOLOGY/NUCLEAR MEDICINE
E ACTION PRESENT YES
EXIT ACTION K RASWLOC
ENTRY ACTION K RAMLC S RASWLOC=""
ROUTINE SET^RAPSET1
DESCRIPTION
This option will allow the user to select a new location as a parameter
without first logging out, then logging back into the package. This option
will kill the variable 'RAMLC' then reset the variable by calling the SET
subroutine in RAPSET1.
CREATOR USER,ONE
TYPE run routine
TIMESTAMP 1994-03-21 13:58:09