LA7 ABNORMAL RESULTS RECEIVED (184)    BULLETIN (3.6)

Name Value
NAME LA7 ABNORMAL RESULTS RECEIVED
MESSAGE
Laboratory results on the following patient have been received via a HL7
     Patient ID: |4|
 
    Specimen ID: |5|
 Collection D/T: |6|
   Test/analyte: |7|
       Producer: |8|
  Producer's ID: |9|
                  
 
     Observation
interface that indicate the results are critical or abnormal. Please use
     -----------
          Value: |10|
          Units: |11|
      Ref range: |12|
          Flags: |13|
the appropriate laboratory option to review these results on this system.
 
  
      Interface: |1|
    File #62.49: |2|
 
   Patient Name: |3|
SUBJECT LAB ABNORMAL/CRITICAL RESULTS RECEIVED
DESCRIPTION
Mail bulletin created by Laboratory package when processing a LEDI
interface type HL7 result (ORU) message which contains laboratory
testing results that are flagged as critical or abnormal.  Values
that are critical will always trigger the alert and bulletin. Values
that are abnormal low or high will be triggered when site has flagged
the corresponding test in AUTO INSTRUMENT file (#62.4), NOTIFY ABNORMAL
FLAGS field (#22) within the CHEM TEST multiple (#30) for the interface.