Name | Value |
---|---|
NAME | ABBOTT IMX UNI |
METHOD | ABBOTT IMX |
OVERLAY DATA | YES |
PROGRAM | LAIMX |
NEW DATA | D NEW^LASET |
RESTART | D RESTART^LASET |
ENTRY for LAGEN ROUTINE | Accession cross-reference |
CROSS LINKED BY | IDE |
INTERFACE NOTES | To enable the interface, press SYSTEM, then FILES, enter 1.18, then press crossed so that it will transmit as a DTE interface. ^LA(19,"I",26) = -------------------------------- ^LA(19,"I",27) = A 0. 6.2 ^LA(19,"I",28) = B 2. 71.4 ^LA(19,"I",29) = C 10. 294.6 ^LA(19,"I",30) = D 30. 720.2 ^LA(19,"I",31) = E 60. 1157.2 ^LA(19,"I",32) = F 100. 1539.7 ^LA(19,"I",33) = ^LA(19,"I",34) = LOC ID ng/mL RATE NOTE ^LA(19,"I",35) = ---------------------------------------- ^LA(19,"I",36) = 2 CONTROL L 3.88 128.0 ^LA(19,"I",37) = 3 CONTROL M 14.17 396.3 ^LA(19,"I",38) = 4 CONTROL H 42.42 923.2 ^LA(19,"I",39) = 5 000000400 0.68 29.5 LOW ^LA(19,"I",40) = 6 000000191 1.24 47.5 LOW ^LA(19,"I",41) = 7 000000301 2.54 88.0 ^LA(19,"I",42) = ^LA(19,"I",43) = ^LA(19,"I",44) = HIGH > 100.000 ng/mL ^LA(19,"I",45) = LOW < 2.000 ng/mL The LAIMX routine is written to process data that is transmitted in ^LA(19,"I",46) = ^LA(19,"I",47) = ^LA(19,"I",48) = TESTS USED TO DATE : 61 ^LA(19,"I",49) = ^LA(19,"I",50) = ^LA(19,"I",51) = ^LA(19,"I",52) = ^LA(19,"I",53) = ] ^LA(19,"I",54) = C ^LA(19,"I",55) = !! the MEIA Quantitative layout as defined in the IMX unidirectional RS232 Interface Guide, pages 7-10. Param 2 holds the number of decimal places for the result. Param 3 holds the number of the test as identified by the instrument. This interface will transmit in a multiple of different formats depending DISPLAY. Enter the password 2215 and press STORE. Set the on the tests being run. This version as of 8/13/93 will handle the data streams for the ASSAY NUMBER, %GHb and %A1C tests, as well as linearity checking. **The %A1C test will require the following code to be placed into Param 1: S LATFLG=1. All other tests should not have this variable set. The linearity functionality can be controlled by entering the following code in Param 1: S LRLN(III)="X.X" where the X.X represents the linearity value for this test. If no linearity checking is to be enabled, Param 1 should be set LRLN(III)="0.0". communication defaults for the COM2 port, turn the IMX system Select TEST: PSA ARE YOU ADDING 'PSA' AS A NEW CHEM TESTS (THE 1ST FOR THIS AUTO INSTRUMENT)? Y (YES) CHEM TESTS NUMBER: 1// PARAM 1: S LRLN(III)="0.1" PARAM 2: 1 PARAM 3: 53 DOWNLOAD CODE: Select TEST: CEA ARE YOU ADDING 'CEA' AS A NEW CHEM TESTS (THE 2ND FOR THIS AUTO off, wait 10 seconds, then turn it back on. This initializes the INSTRUMENT)? Y (YES) CHEM TESTS NUMBER: 2// PARAM 1: S LRLN(III)="1.0" PARAM 2: 1 PARAM 3: 76 DOWNLOAD CODE: Select TEST: FERRITIN ARE YOU ADDING 'FERRITIN' AS A NEW CHEM TESTS (THE 3RD FOR THIS AUTO INSTRUMENT)? Y (YES) CHEM TESTS NUMBER: 3// parameters in memory. PARAM 1: S LRLN(III)="1.0" PARAM 2: 0 PARAM 3: 27 DOWNLOAD CODE: Select TEST: HEMOGLOBIN A1C ARE YOU ADDING '"HEMOGLOBIN A1C' AS A NEW CHEM TESTS (THE 4TH FOR THIS AUTO INSTRUMENT)? Y (YES) CHEM TESTS NUMBER: 4// PARAM 1: S LRLN(III)="0.0" PARAM 2: 1 PARAM 3: 79 DOWNLOAD CODE: Select TEST: (continue entering all tests that this instrument will run using PARAM 3 to hold the ASSAY # assigned by Abbott.) ****************************************************************** SAMPLE DATASTREAM FYI: This instrument produces several different data streams not all of which are currently supported. The interface may be tested by reprinting the results from the last run. ****************************************************************** ^LA(19,"ENV") = VAH^ROU^583VA0^ROU583VA0 ^LA(19,"I") = 55 ^LA(19,"I",0) = 55 ^LA(19,"I",1) = [ ^LA(19,"I",2) = ^LA(19,"I",3) = ^LA(19,"I",4) = DATE: 4/27/93 ^LA(19,"I",5) = TIME: 13:45:30 ^LA(19,"I",6) = ^LA(19,"I",7) = TECH ID : _________ ^LA(19,"I",8) = RGNT LOT: _________ ^LA(19,"I",9) = SERIAL #: 22642 ^LA(19,"I",10) = CRSL ID : 2 ^LA(19,"I",11) = CURVE : 1 ^LA(19,"I",12) = CAL DATE: 4/02/93 ^LA(19,"I",13) = CAL TIME: 10:37:52 ^LA(19,"I",14) = ^LA(19,"I",15) = ASSAY 53 PSA 2245 Revision 1 ***The instrument uses a DCE configuration. Lines 2 and 3 must be ^LA(19,"I",16) = ^LA(19,"I",17) = MODE 1 CALIBRATOR ^LA(19,"I",18) = ^LA(19,"I",19) = LOC ng/mL RATE FACTOR ^LA(19,"I",20) = ---------------------------- ^LA(19,"I",21) = 1 10. 294.6 0.926 ^LA(19,"I",22) = ^LA(19,"I",23) = MODE 1 CALIBRATION CURVE ^LA(19,"I",24) = ^LA(19,"I",25) = CALIB ng/mL AVGR |