{"aaData": [["1", "Invalid Event Protocol IEN", "
\nThe event protocol IEN that was provided could not be found in the\nProtocol file (#101).\n
\n
\n"], ["10", "Missing Processing Routine", "
\nA routine to process the incoming message was not entered in the\nGenerate/Process Routine field in the Protocol file.\n
\n
\n"], ["100", "LLP Could not Enqueue the Message", "
\nThe lower level protocol could not secure internal entry numbers\nto file #870.\n
\n
\n"], ["101", "LLP Unable to Dequeue Message", "
\nLLP unable to dequeue message from file #870\n
\n
\n"], ["102", "Message was NAK'ed", "
\nA message was Nak'ed look at the individual message\nerror field to see why.\n
\n
\n"], ["103", "LLP Exceeded Retry Param", ""], ["104", "Message Low Level NAK'd by Other System", "
\nThe message sent by DHCP was low level NAK'd by the other system.\nLook at this link's output queue for more information.  This information\nwill be found in the STATUS field of individual messages.\n
\n
\n"], ["105", "Tvv is Malformed", "
\nThe lower level protocol header "tvv" is malformed. Check message\nthat was sent to DHCP.\n
\n
\n"], ["106", "LLP Timed Out While Reading in a Message", "
\nLLP exceeded READ TIMEOUT parameter in file 870 while reading in a\nmessage.\n
\n
\n"], ["107", "Message did not Validate, Look at Checksums", "
\nMessage has an incorrect or missing checksum\n
\n
\n"], ["108", "Incorrect Message Received", "
\nThe response message received was not what was expected. This only happens\nwith bi-directional messages.  \n
\n
\n"], ["109", "Duplicate Message", "
\nMessage has already been received and processed.  This is a duplicate.\n
\n
\n"], ["11", "Continuation Pointer Parameter too Long", "
\nThe continuation parameter cannot be more than 180 characters in length.\n
\n
\n"], ["12", "Missing Message Header Segment", "
\nThe header segment for the incoming message is missing.\n
\n
\n"], ["13", "Application Reject Error", "
\nInformation in the message header segment was incorrect or missing.\n
\n
\n"], ["14", "Server Application Missing in Protocol File", "
\nThe Server Application field in the Protocol file (#101) did not have\na value for the event driver protocol identified by the value in the EID\nparameter.\n
\n
\n"], ["15", "No Client", "
\nNo clients are defined for this server protocol. Unless the application\nintends to submit a specific client using the HLL("LINKS") array, this\nmessage should not be sent.\n
\n
\n"], ["16", "Server Protocol Disabled", "
\nThe server protocol has been placed OUT OF SERVICE. The message has been\nrejected by the HL7 Message Service. The sending application must retain\nthe message for later transmission.\n
\n
\n"], ["17", "Error During Generation", "
\nAn error occured during the generation of the message.\n
\n
\n"], ["18", "Error During Processing", "
\nAn error occured during the processing of the message.\n
\n
\n"], ["2", "Event Data Missing", "
\nEvent data (server application, message type or event type) is missing\nfrom the Protocol file (#101).\n
\n
\n"], ["200", "Invalid Internal Entry Number", "
\nThe IEN that was passed to the routine does not exist in the\nassociated file.\n
\n
\n"], ["201", "Missing Internal Entry Number", "
\nThe IEN should have been passed to the routine, but it was not.\nPlease look at the routine to determine which IEN should be used.\n
\n
\n"], ["202", "Invalid Direction", "
\nThe direction of the queue is not in the list:\nIN, OUT, 1, 2\nThe number 1 can be used to specify the "IN" queue\nThe number 2 can be used to specify the "OUT" queue\n
\n
\n"], ["203", "Direction not Given", "
\nA queue direction (IN or OUT) must be passed to tell which\nqueue you are acting on.\n
\n
\n"], ["204", "DICN Error", "
\nFILE^DICN returned a -1 error code for some reason.  Please record\nthe conditions used to create the record and inform an HL7 developer.\n
\n
\n"], ["3", "Missing Generation Routine", "
\nThe Generate/Process Routine field in the Protocol file (#101) is not\nfilled in.\n
\n
\n"], ["4", "Invalid Array Parameter Value", "
\nThe array parameter value is not 'L' for local or 'G' for global.  These\nare the only allowable values.\n
\n
\n"], ["5", "Invalid Priority Parameter Value", "
\nThe priority parameter does not have a first character of 'I' for\nimmediate or 'D' for delayed.  These are the only allowable values.\n
\n
\n"], ["6", "Security Parameter too Long", "
\nThe security parameter cannot be more than 40 characters in length.\n
\n
\n"], ["7", "Missing Input Parameter(s)", "
\nOne or more of the input parameters required for this entry point\nis missing.\n
\n
\n"], ["8", "Invalid or Missing Message Array", "
\nThe local array HLS() or global array ^TMP("HLS",$J) is incomplete or\nmissing.\n
\n
\n"], ["9", "Application Level Error", "
\nAn error ocurred while the application was processing the message.  The\nspecific problem encountered is described in the error message field.\n
\n
\n"]]}