ORB OI EXPIRING - INPT (4681)    PARAMETER DEFINITION (8989.51)

Name Value
NAME ORB OI EXPIRING - INPT
DISPLAY TEXT Flag Item to Send INPT EXPIRING Notifs
MULTIPLE VALUED Yes
INSTANCE TERM Orderable Item
VALUE DATA TYPE yes/no
VALUE DOMAIN Y:yes;N:no
VALUE HELP Enter 'Yes' to trigger an alert for ALL patients, 'No' for only linked patients.
DESCRIPTION
This parameter is used to trigger a notification/alert when a specific
alert.)
 
Users are linked to a patient if the user is the patient's attending
physician, primary inpatient provider, PCMM primary care practitioner,
PCMM associate provider, user is assigned to a position on the patient's
PCMM primary care team or user shares an OE/RR team with the patient.
OE/RR teams are linked to a patient if the patient is on the team. (If
a patient is on a team that has flagged an orderable item, all users on
that team become potential alert recipients.)  Devices (printers, etc.)
are linked to a patient if the device and patient are on the same OE/RR
orderable item is expiring for an inpatient. 
team. 
  
If the value for the orderable item flag is "YES", the entity (user,
team, device) flagging the orderable item becomes a potential alert
recipient for ALL patients.  If the value is "NO", the entity (user,
team, device), flagging the orderable item only becomes a potential
alert recipient if that entity is "linked" to the patient.  (If a device
is added to the potential recipient list, it will always receive the
ALLOWABLE ENTITIES
  • PRECEDENCE:   1
    ENTITY FILE:   USER
  • PRECEDENCE:   2
    ENTITY FILE:   TEAM (OE/RR)
  • PRECEDENCE:   3
    ENTITY FILE:   DEVICE
INSTANCE DATA TYPE pointer
INSTANCE DOMAIN 101.43
INSTANCE HELP Enter the orderable item to trigger a notification when expiring.