MAG DICOM INCORRECT IMAGE CT (1858)    REMOTE PROCEDURE (8994)

Name Value
NAME MAG DICOM INCORRECT IMAGE CT
TAG CORRECT
ROUTINE MAGDRPC8
RETURN VALUE TYPE SINGLE VALUE
AVAILABILITY RESTRICTED
INACTIVE ACTIVE
CLIENT MANAGER 0
WORD WRAP ON TRUE
VERSION 3
SUPPRESS RDV USER SETUP No
DESCRIPTION
 +---------------------------------------------------------------+
 | a medical device.  As such, it may not be changed in any way. |
 | Modifications to this software may result in an adulterated   |
 | medical device under 21CFR820, the use of which is considered |
 | to be a violation of US Federal Statutes.                     |
 +---------------------------------------------------------------+
 
On occasion the software on the DICOM Gateway needs to know
the number of image files that need to be corrected.
This RPC is a general-purpose one that fetches this value from
the VistA system.
 | Property of the US Government.                                |
 | No permission to copy or redistribute this software is given. |
 | Use of unreleased versions of this software requires the user |
 | to execute a written test agreement with the VistA Imaging    |
 | Development Office of the Department of Veterans Affairs,     |
 | telephone (301) 734-0100.                                     |
 |                                                               |
 | The Food and Drug Administration classifies this software as  |
INPUT PARAMETER
  • LOCATION
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    The value of this parameter is a pointer to ^DIC(4).
    This pointer identifies the location at which images were acquired.
    
  • MACHID
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
    The value of this parameter is a string.
    This string (usually only one character) identifies the DICOM
    Gateway for which the request is being posted.
    
RETURN PARAMETER DESCRIPTION
The value of this parameter is an integer number.
This number is the current amount of incorrect image files.