MAG4 CT PRESETS SAVE (1942)    REMOTE PROCEDURE (8994)

Name Value
NAME MAG4 CT PRESETS SAVE
TAG SAVECTP
ROUTINE MAGGTU6
RETURN VALUE TYPE SINGLE VALUE
AVAILABILITY RESTRICTED
DESCRIPTION
 Saves the CT Presets from the Radiology Viewer in Clinical Display
  as site Specific Presets.
INPUT PARAMETER
  • VALUE
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   245
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    This is the string of CT Presets. 
    
  • DATA
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   245
    REQUIRED:   NO
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
     DATA is a set of Flags that determine where the CT Presets will be saved.
     Either as CT PRESETS  or CT PRESETS 2 for Client versions 72 and later
    
RETURN PARAMETER DESCRIPTION
  1^message for success
  0^error message  for error.