INPUT PARAMETER |
-
- PARAMS
- PARAMETER TYPE: LITERAL
- MAXIMUM DATA LENGTH: 255
- REQUIRED: YES
- SEQUENCE NUMBER: 1
- DESCRIPTION:
^ piece
; 2. if the order is a Continuous order key
off of the frequency as follows.
; a.) if the frequency is <24 hours
use the default of 72 hours.
; b.) if the frequency is >= 24 hour,
look back 3.5 times the frequency
; NOTE: ["X#" This Function will search back #
of admins.
; Example call: D FNDACTV^PSBVDLU3(.results,"1234^1U^H^12")
#1 - DFN (required)
#2 - OrderNumber
#3 - Action (status) to search for
#4 - TimeFrame
NOTE: ="FREQ" This Function will use order's
frequency.
; 1. If the order is a PRN, On Call or One-Time
; the look back a default of 72 hours.
|