MAGVC WI UPDATE STATUS (3290)    REMOTE PROCEDURE (8994)

Name Value
NAME MAGVC WI UPDATE STATUS
TAG ACTUPD8
ROUTINE MAGVCWIA
RETURN VALUE TYPE ARRAY
AVAILABILITY RESTRICTED
INACTIVE ACTIVE
VERSION .9
APP PROXY ALLOWED Yes
DESCRIPTION
 +---------------------------------------------------------------+
 | a medical device.  As such, it may not be changed in any way. |
 | Modifications to this software may result in an adulterated   |
 | medical device under 21CFR820, the use of which is considered |
 | to be a violation of US Federal Statutes.                     |
 +---------------------------------------------------------------+
 
This RPC allows the Storage Commit Application to update the STATUS (#3)
of an item in the MAG WORK ITEM file (#2006.941). (MAG*3.0*79).
 | Property of the US Government.                                |
 | No permission to copy or redistribute this software is given. |
 | Use of unreleased versions of this software requires the user |
 | to execute a written test agreement with the VistA Imaging    |
 | Development Office of the Department of Veterans Affairs,     |
 | telephone (301) 734-0100.                                     |
 |                                                               |
 | The Food and Drug Administration classifies this software as  |
INPUT PARAMETER
  • WIIEN
    PARAMETER TYPE:   LITERAL
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    This is the IEN of the MAG WORK ITEM file (#2006.941) entry to be modified.
    
  • STATNEW
    PARAMETER TYPE:   LITERAL
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
    This is the external form of the new STATUS in the MAG WORK ITEM STATUS file
    (#2006.9413).
    
RETURN PARAMETER DESCRIPTION
On error: <0`Errmsg
Success :  0`Echo of IEN`Status update confirmation.