DSIYTDWO DSIYTECH TODAY STATS (3930)    REMOTE PROCEDURE (8994)

Name Value
NAME DSIYTDWO DSIYTECH TODAY STATS
TAG DSIYTECH
ROUTINE DSIYTDWO
RETURN VALUE TYPE GLOBAL ARRAY
WORD WRAP ON TRUE
DESCRIPTION
DSIYTECH
 
Returns statistics by technician.  This RPC can be easily changed if 
different statistics are needed for Work Orders.
 
As of Build 63, it includes:
 
Statistics for Work Orders assigned within the last DAYS # of days
Statistics for Work Orders open for more than DAYS # of days
INPUT PARAMETER
  • NOREC
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   4
    REQUIRED:   NO
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    NOREC
     
    The # of records to return.
    
  • SEC
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   1
    REQUIRED:   YES
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
    SEC
    Make sure the correct DAYS parameter is sent to match the statistic you 
    are trying to return
     
    Which type of data to return?
     
    As of build 63, the available types are:
     
    "A"  Work Orders assigned within the last DAYS # of days
    "O"  Work Orders open for more than DAYS # of days
     
    
  • DAYS
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   3
    REQUIRED:   YES
    SEQUENCE NUMBER:   3
    DESCRIPTION:   
    DAYS
     
    The number of DAYS to use for the statistic being returned.  If the 
    statistic is not based on days, 0 can be sent.
    
  • PMWO
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   1
    REQUIRED:   NO
    SEQUENCE NUMBER:   4
    DESCRIPTION:   
    PMWO
     
    Whether or not to return Preventive Maintenance Work Orders in this 
    statistic.
     
    ""   Only return non-PM Work Orders
    "A"  Return all Work Orders
    "P"  Only return PM Work Orders
    
  • SCHED
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   1
    REQUIRED:   NO
    SEQUENCE NUMBER:   5
    DESCRIPTION:   
    Flag to determine whether to schedule as a report. 1=schedule, 0=do not 
    schedule, defaults to 0.
    
  • ESTART
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   6
    DESCRIPTION:   
    Date/time to start scheduled report.
    
  • STATION
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   12
    REQUIRED:   NO
    SEQUENCE NUMBER:   7
    DESCRIPTION:   
    FILTER BY STATION
    
RETURN PARAMETER DESCRIPTION
RETURN PARAMETER
p3:  Work Order Number
p4:  Task Description
p5:  Date Entered
p6:  Priority
p7:  Location
p8:  Equipment IEN
p9:  Manufacturer
p10: Model
p11: Shop
p12: Technician Name
 
p13: Status
p14: User can edit WO 1=yes
p15: PM Status
p16: Date Closed
 
 
 
DSIYRET("TITLE")=$$$^Dataset Title
DSIYRET(1)=  "-1^Error Message"    for problems
DSIYRET(1)=  "0^Warning Message^Technician Name"  if nothing returned
                    technician name is returned for header
DSIYRET(WONUM)=the following pieces:
 
p1:  Work Order IEN
p2:  Original Work Order #