DSIYTI04 TIWONEW NEW WORK ORD (3932)    REMOTE PROCEDURE (8994)

Name Value
NAME DSIYTI04 TIWONEW NEW WORK ORD
TAG TIWONEW
ROUTINE DSIYTI04
RETURN VALUE TYPE ARRAY
DESCRIPTION
TIWONEW
 
RPC to add a new Work Order if requested during the creating of a Turn-In 
Request.  
INPUT PARAMETER
  • EQIEN
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   11
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    EQIEN
     
    IEN to the Equipment Inventory file ^ENG(6914)
    
RETURN PARAMETER DESCRIPTION
RETURN PARAMETER
 
DSIYRET(1)=  "-1^Error Message"    if errors
DSIYRET(1)=  "0^Warning message"   if warnings
DSIYRET(1)=  "1^Work Order IEN ^ Work Order Number   if successful