DSIYEQ01 EQVAL VAL EQUIP (4049)    REMOTE PROCEDURE (8994)

Name Value
NAME DSIYEQ01 EQVAL VAL EQUIP
TAG EQVAL
ROUTINE DSIYEQ01
RETURN VALUE TYPE ARRAY
DESCRIPTION
EQVAL
 
Validate whether or not an equipment entry is valid
INPUT PARAMETER
  • FORCE
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   1
    REQUIRED:   NO
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    FORCE
     
    Send an "S" if the serial number should be forced if it is a dupe.
    
  • DSIYDAT
    PARAMETER TYPE:   LIST
    MAXIMUM DATA LENGTH:   200
    REQUIRED:   YES
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
    DSIYDAT
     
    For each field, send:
     
    DSIYDAT(FIELD#)=INTERNAL^EXTERNAL
    
RETURN PARAMETER DESCRIPTION
RETURN PARAMETER
 
DSIYRET(1) = 1 if equipment validated correctly
 
DSIYRET(1) = -1  if errors
 
DSIYRET(1) = "D" if dupes exist
 
DSIYRET(2..NN) = additional information on errors or dupes