DSSO TRANS HOME O2 RX (4234)    REMOTE PROCEDURE (8994)

Name Value
NAME DSSO TRANS HOME O2 RX
TAG TRANHO2P
ROUTINE DSSOSU1
RETURN VALUE TYPE GLOBAL ARRAY
AVAILABILITY AGREEMENT
WORD WRAP ON TRUE
DESCRIPTION
This RPC returns home oxygen prescription information for a given 
Prosthetics Appliance/Repair IEN (#660).
INPUT PARAMETER
  • IEN
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    A Prosthetics Appliance/Repair IEN (#660)
    
RETURN PARAMETER DESCRIPTION
Returns an array List[n].
If nothing found, the return will be List[0] = 0^NOTHING TO REPORT.
 
If an error occurs, the return will be List[0] = -1^message.
 
The format of the returned array will be as follows:
  List[0]   = Number of Prescriptions
  List[1]   = Date Written
  List[2]   = Expiration Date
  List[2+n] = Description