DSSO 2319 EDIT 2319 (4356)    REMOTE PROCEDURE (8994)

Name Value
NAME DSSO 2319 EDIT 2319
TAG ED2319
ROUTINE DSSOE29
RETURN VALUE TYPE SINGLE VALUE
AVAILABILITY AGREEMENT
WORD WRAP ON TRUE
DESCRIPTION
This RPC is used to edit a 2319 transaction.
INPUT PARAMETER
  • DSSOIEN
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    This is the #660 IEN.
    
  • DSSORMK
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   61
    REQUIRED:   NO
    SEQUENCE NUMBER:   13
    DESCRIPTION:   
    These are any short remarks for the transaction - 1-61 characters.
    
  • DSSOLOT
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   20
    REQUIRED:   NO
    SEQUENCE NUMBER:   11
    DESCRIPTION:   
    This is the transaction lot number.  The LOT Number must be 1 - 20 
    characters in length and cannot contain "^".
    
  • DSSODES
    PARAMETER TYPE:   LIST
    MAXIMUM DATA LENGTH:   245
    REQUIRED:   NO
    SEQUENCE NUMBER:   16
    DESCRIPTION:   
    This is a word processing field for attaching a longer description to the 
    transaction.
    
  • DSSOCPM
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   8
    DESCRIPTION:   
    This is the CPT Modifier which is used to modify the PSAS HCPCS.  It will 
    be built by selecting from a TreeView during processing.  
     
    Acceptable input values are:
      RT
      LT
      KM
      KN
      RR
    
  • DSSOSER
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   20
    REQUIRED:   NO
    SEQUENCE NUMBER:   10
    DESCRIPTION:   
    This is the serial number.  Serial Number may be from 1 - 20 characters 
    and cannot contain a "^".
     
    If the serial number is longer than 20 characters, use the FIRST 20 
    characters.
    
  • DSSOCON
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   12
    DESCRIPTION:   
    Free text Contract # - must be 1-30 characters.
    
  • DSSOPDS
    PARAMETER TYPE:   LITERAL
    REQUIRED:   NO
    SEQUENCE NUMBER:   14
    DESCRIPTION:   
    MANUFACTURER - to be used for recalls - may be up to 80 characters
     - required
     Stored in PRODUCT DESCRIPTION (file 660 #9.1)
    
  • DSSOEW
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   1
    REQUIRED:   NO
    SEQUENCE NUMBER:   15
    DESCRIPTION:   
    Excluded/Waiver - determines if the item is excluded or a waiver from a 
    national contract - Valid values:  "" - neither; "E" - "EXCLUDED"; "W" - 
    "WAIVER" - not required
    
  • DSSOTYP
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
    This is the transaction type.  It cannot be deleted.
     
    Set of Codes
       I:INITIAL ISSUE
       R:REPLACE
       S:SPARE
       X:REPAIR
       5:RENTAL
    
  • DSSOPCT
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   3
    DESCRIPTION:   
    This is the patient Category. It cannot be deleted.
     
    Set of Codes
        '1' FOR SC/OP;
        '2' FOR SC/IP;
        '3' FOR NSC/IP;
        '4' FOR NSC/OP;
    
  • DSSOSCT
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   4
    DESCRIPTION:   
    This is the special category.
     
    Set of Codes
       '1' FOR SPECIAL LEGISLATION;
       '2' FOR A&A;
       '3' FOR PHC;
       '4' FOR ELIGIBILITY REFORM;
    
  • DSSOSRC
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   5
    DESCRIPTION:   
    This is the source.  It cannot be deleted.
     
    Set of Codes
       'V' FOR VA;
       'C' FOR COMMERCIAL;
    
  • DSSOITM
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   6
    DESCRIPTION:   
    Item of issue - file 661 IEN - cannot be deleted
    
  • DSSOHCP
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   NO
    SEQUENCE NUMBER:   7
    DESCRIPTION:   
    PSAS HCPCS - file 661.1 IEN
    
  • DSSOMOD
    PARAMETER TYPE:   LITERAL
    REQUIRED:   NO
    SEQUENCE NUMBER:   9
    DESCRIPTION:   
    MFG PART NO. - 1-55 characters - required
    Stored in PRODUCT MODEL (660 #9.2)
    
RETURN PARAMETER DESCRIPTION
If successful, the result will be IEN^Record successfully edited.
 
If an error occurs, the result will be -1^error message.