DSIYTI02 TIEQDEL (4559)    REMOTE PROCEDURE (8994)

Name Value
NAME DSIYTI02 TIEQDEL
TAG TIEQDEL
ROUTINE DSIYTI02
RETURN VALUE TYPE SINGLE VALUE
VERSION 1.5
DESCRIPTION
This rpc deletes a specific piece of equipment from a turn-in request.
The rpc checks for error conditions:
1) Lock error
2) Item has an open auto-generated WO.
3) Item was removed from the turn-in by another user - scren not refreshed
4) Item is the only one in the turn-in
 
When the equipment is deleted from turn-in, the TURN-IN DATE is set back 
to null in file 6914.
INPUT PARAMETER
  • TIIEN
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    The IEN index into file #413 - TURN-IN REQUEST
    
  • EQIEN
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
    The IEN index into ^ENG(6914 - the Engineering Inventory file
    
RETURN PARAMETER DESCRIPTION
Returns:
   1 if successful deletion
   -1^reason for failure if not successful (could be lock error)