DSIV CMS MBI PROCESS (4927)    REMOTE PROCEDURE (8994)

Name Value
NAME DSIV CMS MBI PROCESS
TAG CMSMBI
ROUTINE DSIVAUTO
RETURN VALUE TYPE SINGLE VALUE
AVAILABILITY AGREEMENT
WORD WRAP ON TRUE
DESCRIPTION
This RPC will create a CMS MBI ONLY buffer entry. It will then queue a 
subroutine to create a MEDICARE (WNR) buffer entry approximately 5 
minutes later.
INPUT PARAMETER
  • DSIVDFN
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   1
    DESCRIPTION:   
    This is the patient IEN for which you wish to start the CMS MBI process 
    for "No Insurance" buffers.
    
  • DSIVLOC
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   2
    DESCRIPTION:   
    This is the location IEN (#44) for which you wish to start the CMS MBI 
    process for a "No Insurance" buffer entry.
    
  • DSIVDUZ
    PARAMETER TYPE:   LITERAL
    MAXIMUM DATA LENGTH:   30
    REQUIRED:   YES
    SEQUENCE NUMBER:   3
    DESCRIPTION:   
    This is the DUZ for the special "ICB,IB NOINS" user to be used for "No 
    Insurance" automation.
    
RETURN PARAMETER DESCRIPTION
If the process completes successfully, the results will be returned in 
  -1^*error message*
the following format:
 
  *buffer IEN*^CMS MBI ONLY buffer entry created
   ^MEDICARE (WNR) automation process queued: Task #n
 
In the event of an error, the results will be returned in the following 
format: