| DESCRIPTION OF ENHANCEMENTS |
Nov 23, 2016 - V14 - The following defect was corrected by a modification
RISK ANALYSIS: Changes made by patch LR*5.2*462 have no effect on Blood
Bank software functionality, therefore RISK is none.
VALIDATION REQUIREMENTS BY OPTION: Because of the nature of the changes
made, no specific validation requirements exist as a result of
installation of this patch.
Oct 5, 2016 - V12 - This release enhances the "Delete accession #, anat
Patch Components:
-----------------
Files & Fields Associated:
File Name (Number) Field Name (Number) New/Modified/Deleted
------------------ ------------------- --------------------
LABORATORY TEST CPRS SCREEN New
path" option to update CPRS status to discontinued.
(#60) (#21661)
LABORATORY SITE CPRS AP DIALOG ON New
(#69.9) (#21661)
LAB ORDER ENTRY SUBSCRIPT New
(#69) (#21661.71)
CPRS AP SCREEN New
(#21661.72)
SURGEON/PHYSICIAN New
(#21661.73)
SURGERY CASE # New
(#21661.74)
SPECIMEN SUBMITTED New
BY (#21661.811)
BREIF CLINICAL New
HISTORY
(#21661.813)
PREOPERATIVE New
DIAGNOSIS
(#21661.814)
OPERATIVE FINDINGS New
Corrects - Defect 373204 -
(#21661.815)
POST OPERATIVE New
FINDINGS
(#21661.816)
LR CPRS PARAMETERS New
(#69.71)
VLE ANATOMIC PATHOLOGY - VistA LR462/OR405 SURGERY CASE DOES NOT DISPLAY
Forms Associated:
Form Name File # New/Modified/Deleted
--------- ------ --------------------
N/A
Mail Groups Associated:
Mail Group Name New/Modified/Deleted
ON PATIENT DURING SPECIMEN LOGIN IN VISTA
--------------- --------------------
N/A
Options Associated:
Option Name Type New/Modified/Deleted
----------- ---- --------------------
LRXOSX menu Modified
LR7OAP CPRS 60 EDIT edit New
LR7OAP CPRS 60 PRINT run routine New
LR7OAP CPRS DIALOG MENU menu New
LR7OAP CPRS DIALOG PRINT print New
Protocols Associated:
Protocol Name New/Modified/Deleted
------------- --------------------
N/A
Security Keys Associated:
Security Key Name
-----------------
N/A
Fix - M error when the accession has been cancelled using the "Delete
Templates Associated:
Template Name Type File Name (Number) New/Modified/Deleted
------------- ---- ------------------ --------------------
LR7OAPKP DIALOG PRINT LR CPRS PARAMETERS New
SCREENS (#69.71)
LR7OAP CPRS 60 INPUT LABORATORY TEST New
EDIT (#60)
to CRE863^LRAPLG1 routine that will restore the NOW// default instead of
accession #, anat path"option and then a user tries to utilize the "Delete
Additional Information:
N/A
New Service Requests (NSRs):
----------------------------
#20140511
entire order or individual test" option for the same order number. -
The Anatomic Pathology (AP) laboratory service needs a mechanism for
clinicians to provide required patient-specific, procedure-specific, and
specimen-specific information to facilitate specimen processing by
pathologists. This mechanism must be in place for use by the specimen
labeling application in order to generate a primary specimen label that
positively identifies the specimen and accurately associates it with the
patient.
Patient Safety Issues (PSIs):
-----------------------------
there was a typo in the legacy code in the LROS routine.
N/A
Remedy Ticket(s) & Overview:
----------------------------
N/A
Problem:
-------
N/A
Resolution:
----------
N/A
Test Sites:
----------
AP Dialogs w/OR*3.0*405:
North Florida/South Georgia VHCS
Fresno
Northern California
Do no harm testing:
Richmond
Documentation Retrieval Instructions:
-------------------------------------
Updated documentation describing the new functionality introduced by this
patch is available.
Sept 14, 2016 - V11 - Fixes 'no routine' error in APSUB^ORMBLDLR that was
The preferred method is to FTP the files from
ftp://download.vista.domain.ext/.
This transmits the files from the first available FTP server. Sites may
also elect to retrieve software directly from a specific server as
follows:
Albany ftp.fo-albany.domain.ext <ftp://ftp.fo-albany.domain.ext>
Hines ftp.fo-hines.domain.ext <ftp://ftp.fo-hines.domain.ext>
Salt Lake City ftp.fo-slc.domain.ext <ftp://ftp.fo-slc.domain.ext>
still calling LR7OAPMG which was changed with V10 to LR7OAPKM. Problem
Documentation can also be found on the VA Software Documentation Library
at: http://www4.domain.ext/vdl/
Title File Name FTP Mode
-----------------------------------------------------------------------
N/A
Patch Installation:
found by developer once CPRS32 v16 GUI was available. The routine
Pre/Post Installation Overview:
-------------------------------
This patch will install new fields to the LABORATORY TEST (#60), LAB
ORDER ENTRY (#69) and LABORATORY SITE PARAMETERS (#69.9) files. It will
also install a new file, LR CPRS SCREEN (#69.71), four new "LR7OAP"
options, a print template for the LR CPRS SCREEN file and an edit
template for the LABORATORY TEST file.
LR7OAPMG has been added back into this build and will be removed at a
Pre-Installation Instructions:
------------------------------
This patch may be installed with users on the system although it is
strongly recommended that it be installed during non-peak hours when
LAB usage is at a minimum.
Installation Instructions:
--------------------------
This installation will install the components necessary to support the
later date.
CPRS AP Order Dialog functionality released with OR*3.0*405.
1. Choose the PackMan message containing this patch.
2. Choose the INSTALL/CHECK MESSAGE PackMan option.
3. From the Kernel Installation and Distribution System Menu, select
the Installation Menu. From this menu, you may elect to use the
following options. When prompted for the INSTALL NAME enter the patch
LR*5.2*462:
presenting a date and time.
a. Backup a Transport Global - This option will create a backup
message of any routines exported with this patch. It will not
backup any other changes such as DDs or templates.
b. Compare Transport Global to Current System - This option will
allow you to view all changes that will be made when this patch
is installed. It compares all components of this patch
(routines, DDs, templates, etc.).
c. Verify Checksums in Transport Global - This option will allow
you to ensure the integrity of the routines that are in the
transport global.
Sept 8 - V10 - Fixes the following defects:
4. From the Installation Menu, select the Install Package(s) option and
choose the patch to install.
5. When prompted 'Want KIDS to Rebuild Menu Trees Upon Completion of
Install? NO//'
Respond: NO
6. When prompted 'Want KIDS to INHIBIT LOGONs during the install?
NO//'
Defect # 373205 Surgeon Physician not displaying in VistA
Respond: NO
7. When prompted 'Want to DISABLE Scheduled Options, Menu Options,
and Protocols? NO//'
Respond: NO
8. If prompted 'Delay Install (Minutes): (0 - 60): 0//' respond 0.
Post-Installation Instructions:
When submitted by is blank - the Surgeon does not display.
-------------------------------
N/A
Defect # 373204
The surgery case look up fails during log
Sept 1, 2016 - V9 - Fixes Undefined varible.
Defect # - 371975 - Undefined variable when login the specimen in VistA
if Surgeon/Physician is not selected in CPRS.
AUG 25, 2016 - V8 - Fixes default bleed over problems with the
Pathologist and Submitted by fields in AP.
AUG 12, 2016 - V7 - Fixes defect 357639:
Defect: 357639 - VLE ANATOMIC PATHOLOGY - DURING SPECIMEN LOGIN IN VISTA,
PATHOLOGIST FIELD POPULATES NAME OF SURGEON USED FOR A PRIOR ORDER
423457: LI log in, anatomic path field of DATE/TIME SPECIMEN RECEIVED
JULY 17, 2016 - V6 packman created and sent to forum - corrects problem
in LRPLG1 routine.
JULY 15, 2016 - V5 packman created and sent to forum - corrects hard
errors found by QA
JULY 15, 2016 - V4 packman created and sent to forum
JUNE 30, 2016 - V1 packman created and sent to forum
JUNE 29, 2016 - V1 kids file to QA for do no harm testing
The build for this patch is distributed in support of the VLE
Anatomic Pathology order dialog enhancements. It contains a modification
should default to NOW//
to the LABORATORY TEST (#60), LAB ORDER ENTRY (#69), LABORATORY SITE
(#69.9) and adds the new file LR CPRS PARAMETERS (#69.71).
1- Anatomic Pathology specimen log-in option has been modified to
prompt the user for an order number. This order number will be created
by CPRS after patches OR*3.0*405 and LR*5.2*469 are installed.
2- If a user enters an order number, the process deviates from the
current Log-in,anat path option in that it displays any data entered via
CPRS AP order dialog. The fields presented could include any of the
following:
a. SURGEON/PHYSICIAN
b. SPECIMEN SUBMITTED BY
c. SURGERY CASE #
d. SPECIMEN DESCRIPTION/SPECIMEN (multiple)
e. BRIEF CLINCAL DESCRIPTION
f. PREOPERATIVE DIAGNOSIS
g. OPERATIVE FINDINGS
h. POSTOPERATIVE DIAGNOSIS
3- If Surgical Case(s) are found for this patient in the last 7 days
they will be presented to the user for selection. If a case is selected
Oct 6, 2016 - V13 - Added the following as required patches:
the data from the Surgical Case will be displayed and the user will be
asked if they wish to include this in the appropriate field in the
Anatomic Pathology accession.
4- If Surgical Case information is added to Anatomic Pathology
fields it will display first and followed by the information obtained
from the CPRS order.
5- All other data entry/edit actions will be done via existing
Anatomic Pathology options.
LR*5.2*259,291,350,422,433,450
Blood Bank Review:
==================
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*462 does not
contain any changes to the VISTA BLOOD BANK Software as defined by ProPath
standard titled: BBM Team Review of VistA Patches.
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*462 does not
alter or modify any software design safeguards or safety critical elements
functions.
|