| REQUIRED BUILD |
-
- LR*5.2*221
- ACTION: Don't install, leave global
-
- LR*5.2*291
- ACTION: Don't install, leave global
-
- LR*5.2*416
- ACTION: Don't install, leave global
-
- LR*5.2*422
- ACTION: Don't install, leave global
-
- LR*5.2*433
- ACTION: Don't install, leave global
-
- LR*5.2*453
- ACTION: Don't install, leave global
-
- LA*5.2*90
- ACTION: Don't install, leave global
|
| DESCRIPTION OF ENHANCEMENTS |
Associated Patch: LA*5.2*90; which will be installed first as a part of
middleware, sites will be able to switch from using class III interfaces
Parameter Name New/Modified/Deleted
-------------- --------------------
LR MI UI RELEASE DEFAULT NEW
Additional Information:
N/A
New Service Requests (NSRs):
to a UI standard interface. New functionality will be applied that will
----------------------------
NSR #20131213
Carbapenem Resistant Enterobacteriaceae (CRE) Naming Conventions
Electronic Interfacing of Automated Identification and Susceptibility
Testing Instruments
NSR #20140801
Tracking Multi-Drug Resistant Organisms
Patient Safety Issues (PSIs):
-----------------------------
allow for an "MI" subscripted test to be added to the VistA Auto
N/A
Remedy Ticket(s) & Overview:
----------------------------
N/A
Problem:
-------
Instrument file (#64.2). There will also be enhanced result processing and
N/A
Resolution:
----------
N/A
Test Sites:
----------
Tampa (alpha)
Iowa City
verify/release functions (see LA*5.2*90 patch descriptions for additional
Lexington
Software and Documentation Retrieval Information
==============================
VistA Laboratory patch LR*5.2*474 software is distributed by Host File,
along with LA*5.2*90.
The preferred method is to retrieve files from download.vista.domain.ext.
This transmits the files from the first available server. Sites may
also elect to retrieve files directly from a specific server.
details).
Sites may retrieve the software and/or documentation directly using
Secure File Transfer Protocol (SFTP) from the ANONYMOUS.SOFTWARE directory
at the following OI Field Offices:
Albany: fo-albany.domain.ext
Hines: fo-hines.domain.ext
Salt Lake City: fo-slc.domain.ext
File Name Contents Retrieval Format
------------------ -------------------- ----------------
LAB_MICRO_INTERFACE_ Host File containing ASCII
RELEASE_1_0.KID KIDS software distribution
LAB_MICRO_INTERFACE_RELEASE_1_0_DOCS.ZIP, which contains both .pdf and
.doc formatted file of the following documents. Retrieval format is
BINARY:
Lab Micro Interface Release 1.0 User Guide
Lab Micro Interface Release 1.0 Technical Manual and Security Guide
The build for this patch is distributed in support of the VistA
Lab Micro Deployment, Installation, Back-Out, and Rollback
Guide
The VistA Documentation Library (VDL) web site will also contain the
above referenced documents. This website is usually updated within 1-3
days of the patch release date. The VDL web address for Laboratory
Universal Interface user documentation is:
http://www.domain.ext/vdl/application.asp?appid=120
Note: These previously released documents contain configuration and
Laboratory Enhancement (VLE) Microbiology/Data Innovations interface
mapping information that is useful to the implementation of the Universal
Interface for Microbiology tests.
------------------------------------------------------------------------
LEDI IV Installation Guide LAB_LEDI_IV_IG.PDF binary
LEDI IV User Manual LAB_LEDI_IV_UM.PDF binary
LEDI IV Update AP/MICRO LEDI_IV__AP__MICRO_ binary
Configuration Guide CONFIGURATION_GUIDE.PDF binary
Patch Installation:
utilizing the Laboratory Universal Interface.
-------------------
Pre/Post Installation Overview:
-------------------------------
This patch, LR*5.2*474 is part of a combined build for the Laboratory
Microbiology Interface Enhancement patch.
This patch install must be coordinated with the Laboratory ADPAC to
ensure that all Lab Interface related activities are halted.
this combined build.
This installation will modify the Enter/verify data (auto instrument)
option for the Microbiology Universal Interface process by providing the
following release options:
Select RELEASE action: Edit (full)// ?
Entering 0 will abort review/release.
Entering 1 will allow release 'as is' with no editing.
Entering 2 will allow you to enter/edit comments then release.
The patch provide new functionality provides for the Enter/Verify data
Entering 3 will allow you to enter full edit, similar to 'Results entry'
option.
Selections 1-3 will allow editing of status and approved date/time.
Select one of the following:
0 Quit
1 Release
2 Comments/Release
(Auto Instrument) option which will allow the technologist with the
3 Edit (full)
Pre-Installation Instructions:
------------------------------
Ensure that all Lab Interface activity has been halted !!
This would include:
-Editing of an Auto Instrument file entry,
-Turn off the Auto Downloading process to prevent the building and
authority to release three release actions.
downloading
of a Load/Worklist to the Instrument Manager.
-Shut down all LA7UI logical links and any other HL7 process (HLZTCP or
HLLP processes)
to prevent the processing of result messages from the IM.
This patch may be installed with users on the system as long as the above
process controls have been followed.
Installation Instructions:
--------------------------
This patch may be installed with users on the system although it is
recommended that it be installed during non-peak hours to minimize
potential disruption to users. This patch should take less than 5
minutes to install.
1. DOWNLOAD HOST KIDS FILE
----------------------
Download the KIDS file LAB_MICRO_INTERFACE_RELEASE_1_0.KID from
the ANONYMOUS.SOFTWARE directory of Albany, Hines, or the Salt
Lake OIFO to the appropriate directory on your system.
2. LOAD DISTRIBUTION
-----------------
Use the 'LOAD A DISTRIBUTION' option on the KIDS
INSTALLATION menu, and enter: the directory onto which you
have downloaded the host file, followed by
LAB_MICRO_INTERFACE_RELEASE_1_0.KID, the host file name.
Blood Bank Review:
3. START UP KIDS
-------------
Start up the Kernel Installation and Distribution System Menu
[XPD MAIN]:
Edits and Distribution ...
Utilities ...
Installation ...
Select Kernel Installation & Distribution System Option:
==================
Installation
-------------
Load a Distribution
Print Transport Global
Compare Transport Global to Current System
Verify Checksums in Transport Global
Install Package(s)
Restart Install of Package(s)
Unload a Distribution
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*474 does not
Backup a Transport Global
4. Select Installation Option:
---------------------------
a. Use the Load a Distribution and select Host File:
LAB_MICRO_INTERFACE_RELEASE_1_0.KID
b. Backup a Transport Global - This option will create a backup
message of any routines exported with this patch. It will not
backup any other changes such as DDs or templates.
contain any changes to the VISTA BLOOD BANK Software as defined by ProPath
c. Compare Transport Global to Current System - This option will
allow you to view all changes that will be made when this patch
is installed. It compares all components of this patch
(routines, DDs, templates, etc.).
d. Verify Checksums in Transport Global - This option will allow
you to ensure the integrity of the routines that are in the
transport global.
5. When prompted 'Want KIDS to Rebuild Menu Trees Upon Completion of
standard titled: BBM Team Review of VistA Patches.
Install? NO//'
Respond: NO
6. When prompted 'Want KIDS to INHIBIT LOGONs during the install?
NO//'
Respond: NO
7. When prompted 'Want to DISABLE Scheduled Options, Menu Options,
and Protocols? NO//'
Respond: NO
8. If prompted 'Delay Install (Minutes): (0 - 60): 0//'
Respond: 0.
Post-Installation Instructions:
-------------------------------
ADPAC and Microbiology Tech instructions:
1. After data has been received from the Data Innovations for an
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*474 does not
automated Microbiology instrument, the releasing Microbiology Technologist
will be presented with the following options:
Select RELEASE action: Edit (full)// ?
Entering 0 will abort review/release.
Entering 1 will allow release 'as is' with no editing.
Entering 2 will allow you to enter/edit comments then release.
Entering 3 will allow you to enter full edit, similar to 'Results entry'
option.
alter or modify any software design safeguards or safety critical elements
Selections 1-3 will allow editing of status and approved date/time.
Select one of the following:
0 Quit
1 Release
2 Comments/Release
3 Edit (full)
Select RELEASE action: Edit (full)// 0 Quit
functions.
Do you want to PURGE these results? NO//
2. A new parameter LR MI UI RELEASE DEFAULT is included with this
patch and it provides the VAMC site the ability to set the release default
at the package and user levels.
Example configuration:
Select OE/RR interface parameters <TEST ACCOUNT> Option: Select Lab
liaison menu <TEST ACCOUNT> Option: OE/RR interface parameters
EH Edit HOSPITAL SITE parameters
AS Edit a lab administration schedule
IL Inquire to a Lab administration schedule
CC Update CPRS Parameters ...
Select OE/RR interface parameters <TEST ACCOUNT> Option: CC Update CPRS
RISK ANALYSIS: Changes made by patch LR*5.2*474 have no effect on Blood
Parameters
PA Update CPRS with Lab order parameters
SI Update CPRS with Single Lab test
UP Update CPRS with all Lab test parameters
DO Domain Level Parameter Edit
LO Location Level Parameter Edit
PP Package Level Parameter Edit
UL Display Lab User Parameters
Bank software functionality, therefore RISK is none.
Select Update CPRS Parameters <TEST ACCOUNT> Option: PP Package Level
Parameter Edit
Lab Package Level Parameters for Package: LAB SERVICE
--------------------------------------------------------------------------
Collect on Monday YES
Collect on Tuesday YES
Collect on Wednesday YES
Collect on Thursday YES
Collect on Friday YES
Collect on Saturday YES
Collect on Sunday YES
Lab Collects on Holidays YES
Lab Collect Days Allowed in Future 7
Maximum Days for Continuous Orders
Default manual verify method
Default load/work list verify method
Display Provider in Micro Result Entry
Default Micro Instrument Release Action VITEK Edit (full)
VALIDATION REQUIREMENTS BY OPTION: Because of the nature of the changes
Prompt CPRS Alert in Micro Result Entry Don't Ask
Prompt CPRS Alert in CH Result Entry
EGFR Creatinine IDMS-traceable Method
EGFR Patient's Age Cutoff
EGFR Result Cutoff
Send an alert after AP release
Default AP Report Selection Prompt
Ask Performing Lab AP YES
Ask Performing Lab Micro YES
Print SNOMED Code System SNOMED I
The build for this patch is distributed as part of a multi-package build
made, no specific validation requirements exist as a result of
Document Surgery Package Case Info NO
Chemistry GUI Report Right Margin
Microbiology GUI Report Right Margin
AP GUI Report Right Margin
Method of Assigning AP Accession Number
Default Accessioning Specimen
Default Accessioning Collection Sample
Default Accessioning Lab Test
Exclude removed tests from building
Use default accession dates
installation of this patch.
Print Reporting/Printing Facility None
Days to keep of instrument data 1 2
Lab STS Default Mapping Files Directory
Lab STS Default Mapping Filespec *.TXT
--------------------------------------------------------------------------
COLLECT MONDAY: YES//
COLLECT TUESDAY: YES//
COLLECT WEDNESDAY: YES//
COLLECT THURSDAY: YES//
COLLECT FRIDAY: YES//
COLLECT SATURDAY: YES//
COLLECT SUNDAY: YES//
IGNORE HOLIDAYS: YES//
LAB COLLECT DAYS ALLOWED IN FUTURE: 7//
MAXIMUM DAYS FOR CONTINUOUS ORDERS:
Default manual verify method:
For Default load/work list verify method -
Select Accession Area:
Display Provider in Micro Result Entry:
For Default Micro Instrument Release Action -
Select Load/Work List: VITEK
Load/Work List: VITEK// VITEK VITEK
Default load/work list verify method: Edit (full)//
For Default Micro Instrument Release Action -
Select Load/Work List:
NOTE: This parameter will allow the default release action to be
Patch Components:
Load/Work List specific.
3. Setting the default release action for a user:
Select Information-help menu <TEST ACCOUNT> Option: PP General Lab User
Parameters
Lab User Level Parameters for User: TECH,MICRO
--------------------------------------------------------------------------
-----------------
Default lab label printer
Display previous comments for test
Default Performing Laboratory
Ask Performing Lab AP
Ask Performing Lab Micro
Display Provider in Micro Result Entry
Prompt CPRS Alert in CH Result Entry
Prompt CPRS Alert in Micro Result Entry
Default Micro Instrument Release Action VITEK Release
Default AP Report Selection Prompt
None
Send an alert after AP release
Default Accessioning Specimen
Default Accessioning Collection Sample
Default Accessioning Lab Test
Exclude removed tests from building
Use default accession dates
Lab Messaging - Parse HL7 Messages
Lab Messaging - Display using Browser
Lab Messaging - Show Identifiers
Chemistry GUI Report Right Margin
Microbiology GUI Report Right Margin 132
AP GUI Report Right Margin 240
Lab STS Default Mapping Files Directory
Lab STS Default Mapping Filespec
--------------------------------------------------------------------------
For Default lab label printer -
Select Division:
For Display previous comments for test -
Files & Fields Associated:
Select Laboratory Test:
Default Performing Laboratory:
Ask Performing Lab AP:
Ask Performing Lab for MICRO:
Display Provider in Micro Result Entry:
Send CPRS Alert in CH Result Entry:
Send CPRS Alert in Micro Result Entry:
For Default Micro Instrument Release Action -
Select Load/Work List: VITEK
Are you adding VITEK as a new Load/Work List? Yes// YES
Load/Work List: VITEK// VITEK VITEK
Default load/work list verify method: Release
For Default Micro Instrument Release Action -
Select Load/Work List:
NOTE: This parameter will allow the default release action to be
Load/Work List specific.
AP Report Selection Default: ^
that contains LA*5.2*90 and LR*5.2*474. The build contains functionality
File Name (Number) Field Name (Number) New/Modified/Deleted
------------------ ------------------- --------------------
N/A
Forms Associated:
Form Name File # New/Modified/Deleted
--------- ------ --------------------
N/A
that will allow Microbiology instrumentation to utilize the Lab Universal
Mail Groups Associated:
Mail Group Name New/Modified/Deleted
--------------- --------------------
N/A
Options Associated:
Interface.
Option Name Type New/Modified/Deleted
----------- ---- --------------------
N/A
Protocols Associated:
Protocol Name New/Modified/Deleted
------------- --------------------
N/A
Security Keys Associated:
Security Key Name
-----------------
N/A
By utilizing the Universal Interface and Instrument Manager (IM)
Templates Associated:
Template Name Type File Name (Number) New/Modified/Deleted
------------- ---- ------------------ --------------------
LR USER PARAMETER TEMPLATE NEW
FILE (8989.52)
LR PKG PARAMETER TEMPLATE NEW
FILE (8989.52)
Parameters Associated:
|