| DESCRIPTION OF ENHANCEMENTS |
This patch will resolve the following issue.
INC0962039 - WNY - Vista Not Updating BCBU orders when patients are
discharged/deceased
INC1002829 - BCBU patient census not updating
(Duplicate)
Problem:
--------
An issue was discovered with the Barcode Medication Administration (BCMA)
Backup System (BCBU) after the installation of patch PSB*3*105. After the
patient is discharged or a date of death is entered for him/her the patient
data is not being properly removed from the BCBU workstation. In the case of
discharged patient that are later admitted or have a clinic appointment their
orders from their previous admission are still visible on the BCBU
workstation and are listed on the patient's Medication Administration Reports
(MAR).
Resolution:
-----------
Removed the filter introduced by PSB*3*110 to prevent alerts from being
generated for patient movements if the patient is no longer inpatient. The
INC0962039 - WNY - Vista Not Updating BCBU orders when patients are
reason is because such filter prevented patient discharge events, which are
handled as patient movements, from removing he patient's data from the
BCBU workstation. The filter was re-introduced at the Alert generation point
and exclude patient discharge movements.
Technical Resolution:
---------------------
Changed the routine ALPBCBU to remove the filter from the PMOV line tag and
placed a check in the ERRLOG line tag to prevent Alerts for patient movement
events after the patient had already been discharged.
discharged/deceased
INC1002829 - BCBU patient census not updating
(Duplicate)
Defect Tracking System Ticket(s) & Overview:
--------------------------------------------
|