| DESCRIPTION OF ENHANCEMENTS |
This patch will resolve the following issue.
Problem:
--------
Captain James A. Lovell Federal Health Care Center reported a problem with
the BCBU Initialize options below:
Default Workstation Initialize [PSB BCBU INIT WRKSTN DFT]
Divisional Workstation Initialize [PSB BCBU INIT WRKSTN DIV]
Whenever these options were executed and one or more Workstation Link were
selected for the initialization the option still generated and sent HL7
message updates to all other existing BCBU Workstation Links.
Solution:
--------
The two Workstation Initialize options above were modified to screen out any
Workstation Link not selected from the HL7 update if the user selects one or
more specific Workstation Link(s) to update when executing these options. In
other words, only the selected Workstation Link(s) will be initialized.
INC2794138 - When BCBU init is ran and only one HL7 link is entered it still
Technical Resolution:
---------------------
The routines ALPBIN, ALPBIND and ALPBINP were modified to keep track and
screen out Workstation Link(s) not selected for the HL7 initialization
update.
updates numerous links
Defect Tracking System Ticket(s) & Overview:
--------------------------------------------
INC2794138 - When BCBU init is ran and only one HL7 link is entered it still
updates numerous links
|