| DESCRIPTION OF ENHANCEMENTS |
This patch will resolve the following issues:
Problem:
-------
The Audie L. Murphy Memorial Veterans' Hospital reported that when they
submitted a missing dose for an inpatient order with 3 or more dispense drugs
associated with it and later scanned the medication received BCMA Med Logs only
had a record of the first and last dispense drug associated with the order.
Some orders require a combination of dispense drugs to achieve the exact dose
ordered. For example: an order of 75MG for Prednisone would require a
combination of 3 20MG tablets, plus 1 10MG table plus 1 5MG tablet. Upon
research it was determined that this issue was introduced by patch PSB*3*99,
issue #3 (I9892810FY16). In addressing that issue the patch accidentally
introduced the issue reported above. This issue is also being considered a
Patient Safety Issue (PSI) and the number assigned by the Patient Safety team
is HITPS-7596.
Resolution:
----------
The software was modified to prevent the deletion of some of the dispense
drugs in the BCMA Medication Log when 3 or more dispense drugs are marked
1) INC14580997 - BCMA Missing Dose Routing BUG
missing doses on an order and later are scanned.
Technical Resolution:
--------------------
Modified the line UPDATED+97 on the routine PSBML2 to not mark a dispense drug
to be deleted from the BCMA Medication Log if it was previously populated with
an valid dispense drug in the order.
Patient Safety Issues (PSIs):
HITPS-7596
-----------------------------
HITPS-7596
Defect Tracking System Ticket(s) & Overview:
--------------------------------------------
1) INC14580997 - BCMA Missing Dose Routing BUG
HITPS-7596
|