SD*5.3*790 (12350)    BUILD (9.6)

Name Value
NAME SD*5.3*790
DATE DISTRIBUTED 2021-08-11 00:00:00
PACKAGE FILE LINK SCHEDULING
REQUIRED BUILD
  • SD*5.3*788
    ACTION:   Don't install, remove global
TYPE SINGLE PACKAGE
ALPHA/BETA TESTING NO
DESCRIPTION OF ENHANCEMENTS
 
  VSE-979
 
4) Jira #VSE-1094
 
Problem: When scheduling an future appointment using VistA for a clinic 
that has a future re-activation date, the resource is not linked to the 
appointment.
 
Resolution: When adding the resource, do not check the inactivation 
status.
 
  VSE-1127
5) Jira #VSE-1127
 
Problem/Task:
 The RECALL REMINDER (#403.5) file data, may sometimes be unavailable 
 because it was removed upon making an appointment.
 
Resolution:
 Created an RPC (SDEC RECALLRMV BY DFN JSON) to retrieve the needed data 
 from the RECALL RMINDER REMOVED (#403.56) file.
 
 
6) Jira #VSE-1144
 
Problem:
 
Resolution:
 
7) Jira #VSE-1146
 
Problem: Eligibility code is not returned when an appointment does not 
have resource.
Sprint 15:
 
Resolution: When no resource is found, get Hospital Location from the 
Appointment sub file of the Patient file.  Use the Hospital Location to 
get the Enrollment Code and Resource.
 
8) Jira #VSE-1154
 
Problem:
 
Resolution:
  VSE-985
 
9) Jira #VSE-1155
 
Problem:
 
Resolution:
 
10) Jira #VSE-1157
 
Problem:
  VSE-1037
Ensure Contact Attempts for Recall Requests are included when converted 
to APPT
 
 
Resolution:
Modified the Request Pointer in SDEC CONTACT (#409.86) file to reflect 
the appropriate SDEC APPOINTMENT (#409.84) file entry.
 
 
11) Jira #VSE-1171
  VSE-1087
 
Problem:
Based on the Research performed in VSE-235 it was determine that a check 
on the Appt Status needs to be added to the SDEC APPADD RPC to prevent it 
from returning the original Appt for the Same Patient, Date and Clinic 
when the original Appt has a status of Cancelled.
 
Resolution:
Updated APPTGET^SDECUTL to include a status check for the following 
statuses:
  VSE-1094
 
C:CANCELLED BY CLINIC
CA:CANCELLED BY CLINIC & AUTO RE-BOOK
N:NO-SHOW
NA:NO-SHOW & AUTO RE-BOOK
PC:CANCELLED BY PATIENT
PCA:CANCELLED BY PATIENT & AUTO-REBOOK
 
12) Jira #VSE-1172
 
  VSE-1144
Problem:
There were 2 issues identified during the analysis on VSE-235:
 1. Locking/Unlocking of ^SDEC(409.84 was using variable DFN instead of
    SDECAPPTID.
 2. A more efficient cross reference could be used for the 
    APPTGET^SDECUTL subroutine.
 
Resolution:
 1. Routine SDEC07 was updated to use SDECAPPTID when locking or 
    unlocking #409.84.
  VSE-1146
 2. Routine SDECUTL was updated to use the APTDT x-ref.
 
 
) Jira #VSE-
 
Problem:
 
Resolution:
 
) Jira #VSE-
VS GUI v. 1.7.9 Release
  VSE-1154
 
Problem:
 
Resolution:
 
) Jira #VSE-
 
Problem:
 
Resolution:
  VSE-1155
 
) Jira #VSE-
 
Problem:
 
Resolution:
 
) Jira #VSE-
 
Problem:
  VSE-1157
 
Resolution:
  VSE-1171
  VSE-1172
 
FILES:
======
          
 
 
ROUTINES:
=========
          VSE-1171 - updated to add a check for
Cancelled Appts to the
                     SDEC APPADD RPC
SDEC07 - VSE-1172 - updated to address Locking/Unlocking issue from
                    VSE-235
SDEC52CRMVJSON - VSE-1127 - Added logic to retrieve the RECALL REMINDER 
                 data from the RECALL REMINDER REMOVED (#403.56) file.
SDEC55A          VSE-1146
For tracking purposes, please add component(s) and note the associated
SDESAPPTUTIL     VSE-1146
SDESCHECKIN      VSE-985
SDEC50           VSE-985
SDEC08           VSE-1157
 
 
 
OPTIONS:
========
 
Jira task(s) out to the right on the same line.
 
 
REMOTE PROCEDURES:
==================
  
SDEC GET RECALLRMV BY DFN JSON- VSE-1127 Retrieve RECALL REMINDER data 
                          from RECALL REMINDER REMOVED (#403.56) file.
 
 
 
 
 
JIRA tasks:
-----------
1) Jira #VSE-???(979)
 
Problem/Task:
  When doing a drag and drop with a recall appointment, the request is 
  created on the RM Grid and not removed when the appointment is made.  
  
  This should be a behind the scene action...it shouldn't display on the 
Sprint & Associated Tasks:
  RM Grid.
 
Resolution:
 
 
2) Jira #VSE-985
 
Problem: Display a visual indicator for Pre-Checkin Step in VS GUI.
 
Resolution: Update SDEC FAPPSGET RPC to include a new field that will 
==========================
indicate if the patient has completed pre-checkin step for the 
appointment.
 
2) Jira #VSE-1037
 
Problem: The job SDRR CLEANUP needs to be disabled so that it cannot be 
set up to run as a nightly job at sites. Follow the same pattern that 
Brian Rene did for the EWL option.
 
Resolution: Update OPTION SDRR CLEAN-UP to include OUT OF ORDER MESSAGE 
Sprint 14:
so that it will not be available.  Also update routine SDRRCLR to QUIT 
at the top of the routine so that it will not run. These updates 
disable the menu option from being run manually or called from the 
nightly Schedule/Unschedule Option under the TASKMAN MANAGEMENT option.
 
3) Jira #VSE-1087
 
Problem:
 
Resolution:
TRACK PACKAGE NATIONALLY YES
XPI1 NO
XPO1 YES
XPZ1 NO
SEQ# 643
BUILD COMPONENTS
  • ENTRIES:
    • SDECRPC
      ACTION:   SEND TO SITE
    • SDRR CLEAN-UP
      ACTION:   SEND TO SITE
  • ENTRIES:
    • SDEC GET RECALLRMV BY DFN JSON
      ACTION:   SEND TO SITE
    • SDEC APPDEL
      ACTION:   SEND TO SITE
    • SDES CLINIC RSC SEARCH JSON
      ACTION:   SEND TO SITE
  • ENTRIES:
    • SDECUTL
      ACTION:   SEND TO SITE
      CHECKSUM:   B107666261
    • SDEC50
      ACTION:   SEND TO SITE
      CHECKSUM:   B190831177
    • SDEC07
      ACTION:   SEND TO SITE
      CHECKSUM:   B182578667
    • SDRRCLR
      ACTION:   SEND TO SITE
      CHECKSUM:   B15573877
    • SDES01C
      ACTION:   SEND TO SITE
      CHECKSUM:   B8699364
    • SDES
      ACTION:   SEND TO SITE
      CHECKSUM:   B3148087
    • SDECVVS
      ACTION:   SEND TO SITE
      CHECKSUM:   B36137041
    • SDESSEARCH
      ACTION:   SEND TO SITE
      CHECKSUM:   B3328090
    • SDES25
      ACTION:   SEND TO SITE
      CHECKSUM:   B144656924
    • SDES30
      ACTION:   SEND TO SITE
      CHECKSUM:   B2568685
    • SDESCKNSTEP
      ACTION:   SEND TO SITE
      CHECKSUM:   B44239090
    • SDEC52CJSON
      ACTION:   SEND TO SITE
      CHECKSUM:   B43237930
    • SDECRECREQ
      ACTION:   SEND TO SITE
      CHECKSUM:   B8673461
    • SDEC52CRMVJSON
      ACTION:   SEND TO SITE
      CHECKSUM:   B48950491
    • SDEC55A
      ACTION:   SEND TO SITE
      CHECKSUM:   B113154623
    • SDESAPPTUTIL
      ACTION:   SEND TO SITE
      CHECKSUM:   B3286700
    • SDEC
      ACTION:   SEND TO SITE
      CHECKSUM:   B136529127
    • SDEC08
      ACTION:   SEND TO SITE
      CHECKSUM:   B180017805
POST-INSTALL ROUTINE SDEC790P
DELETE POST-INIT ROUTINE No