| DESCRIPTION OF ENHANCEMENTS |
This enhancement to the VISTA Surgery package includes a new field
(137.45). If defined for a local specialty, the software will
automatically enter NO in the ROBOTIC ASSISTANCE (Y/N) field when
a surgery case is created for the selected specialty.
Update to transmission code to restrict date/time field 613 to 12
characters.
Update to Nurse Intraoperative report to have Laser Duration notes as
seconds (not minutes). Update to file #130.11, field #14 to reflect this
change.
ROBOTIC ASSISTANCE (Y/N) for tracking whether robotic assistance was used
Update to include a search for any height for the patient, not just a
height in the past year.
when completing a surgery procedure. The new field is included on the
Operation, Operation Short Screen, and Nurse Intraoperative Report
options within the Operation Menu and is required to be entered prior to
signing the Nurse Intraoperative Report. The field is also included on
Non-Cardiac and Cardiac Risk Assessment data entry options. This
indicator is transmitted to VASQIP for all cases. A new field, ROBOTIC
DEFAULT (#12) has been added to the LOCAL SURGICAL SPECIALTY file
|