SR*3.0*204 (12986)    BUILD (9.6)

Name Value
NAME SR*3.0*204
DATE DISTRIBUTED 2022-06-30 00:00:00
PACKAGE FILE LINK SURGERY
REQUIRED BUILD
  • SR*3.0*142
    ACTION:   Don't install, remove global
TYPE SINGLE PACKAGE
DESCRIPTION OF ENHANCEMENTS
The patch addresses two (2) issues: 
    DELIVERED field (#9) in the LASER PERFORMED multiple (#135) in the 
    SURGERY FILE (#130). Specifically: the request is to increase the 
    largest allowable value to 99999.9.
 
1.  One Liner (1-Liner) cases are not transmitting to the National Risk
    Assessment database because the SURGERY FILE (#130) AQ XREF is being 
    killed and not reset when the TIME PAT OUT OR field (#.232) in the 
    SURGERY FILE (#130) is edited for a surgery case with a signed Nurse
    Intraoperative Report with coding complete.
 
2.  A request is to increase the numeric upper limit of the TOTAL JOULES
TRACK PACKAGE NATIONALLY YES
FILE
  • DD NUMBER:
    • LASER PERFORMED (sub-file)
      FIELD NUMBER:
      • TOTAL JOULES DELIVERED
    UPDATE THE DATA DICTIONARY:   YES
    SEND SECURITY CODE:   NO
    SEND FULL OR PARTIAL DD:   PARTIAL
    DATA COMES WITH FILE:   NO
    MAY USER OVERRIDE DATA UPDATE:   NO
SEQ# 189
BUILD COMPONENTS
  • ENTRIES:
    • SROPCEX
      ACTION:   SEND TO SITE
      CHECKSUM:   B5945124