PSO*7.0*736 (13673)    BUILD (9.6)

Name Value
NAME PSO*7.0*736
DATE DISTRIBUTED 2024-03-07 00:00:00
PACKAGE FILE LINK OUTPATIENT PHARMACY
REQUIRED BUILD
  • PSO*7.0*643
    ACTION:   Don't install, remove global
  • PSO*7.0*441
    ACTION:   Don't install, remove global
TYPE SINGLE PACKAGE
ALPHA/BETA TESTING NO
DESCRIPTION OF ENHANCEMENTS
The OneVA Pharmacy application provides the Veterans Health 
patient's active and refillable prescriptions. The HDR/CDS provides a
patient's active and refillable prescriptions. The OneVA Pharmacy message
flow enables the secure, bi-directional exchange of electronic health
records between local/remote VistA Servers, and between VistA servers and
HDR.
 
The OneVA software currently uses IBM Websphere as the messaging system. 
The IBM Websphere messaging system is being decommissioned. This patch 
provides the move from using IBM Websphere to using the Veterans Data 
Information Exchange (VDIF).
Administration (VHA) with the capability to allow Veterans travelling 
 
The software changes include the following:
1. Routine PSORRX1 - DNS value modified at REMOTERX+18
2. Routine PSORRX1 - modified argument list and corresponding references 
   to the DRUGMTCH function
3. Routine PSORRX1 - modified to handle HL7 messages with possible 
   overflow nodes at RXPRSE+4
4. Routine PSOHLDS6 - modified to handle HL7 messages with possible
   overflow nodes at HOST+2 
5. Routine PSOORUT1 - modified "PROVIDER HOLD" status abbreviation from 
across the United States to refill/partial fill their active VA
   "PH" to "HP" at SHOWREM+13
6. Routine PSOORUT1 - added "DISCONTINUED BY PROVIDER", "DISCONTINUED
   (EDIT)", and "NON-VERIFIED" status abbreviations at SHOWREM+13
7. HL LOGICAL LINK entry - the post-install routine POST^PSO736PO updates
   the PSORRXSEND entry of the HL LOGICAL LINK (#870) file.  The following
   fields will be updated to reflect VDIF production IP address and port 
   values when installed in the site's production account:  DNS DOMAIN,
   TCP/IP ADDRESS, and TCP/IP PORT
prescription at any VA Pharmacy regardless of where the prescription
originated. The OneVA Pharmacy application design consists of 3 main
components: VistA Medication Profile screen, Health Data Record Clinical
Data Service (HDR/CDS), and OneVA Pharmacy message flow. The VistA
Medication Profile screen expands available pharmacy information in VistA
to provide pharmacists direct access to query, and refill/partial fill
TRACK PACKAGE NATIONALLY YES
XPI1 NO
XPO1 NO
XPZ1 NO
SEQ# 619
BUILD COMPONENTS
  • ENTRIES:
    • PSORRX1
      ACTION:   SEND TO SITE
      CHECKSUM:   B156717075
    • PSOORUT1
      ACTION:   SEND TO SITE
      CHECKSUM:   B146931226
    • PSOHLDS6
      ACTION:   SEND TO SITE
      CHECKSUM:   B7594556
POST-INSTALL ROUTINE POST^PSO736PO
DELETE POST-INIT ROUTINE No
RESTORE ROUTINE RESTORE^PSO736RR