| DESCRIPTION OF ENHANCEMENTS |
Reference NOIS: HIN-0297-40272, DEN-0697-51422
This patch to the Laboratory package does not contain any changes to the
DEVICE: HOME// TELNET
LR*5.2*155
-------------------------------------------------------------------------
Install Started for LR*5.2*155 :
Mar 26, 1998@14:02:16
VISTA BLOOD BANK Software as defined by VHA Directive 97-033 titled VISTA
Installing Routines:
Mar 26, 1998@14:02:17
Updating Routine file...
Updating KIDS files...
LR*5.2*155 Installed.
Mar 26, 1998@14:02:18
BLOOD BANK SOFTWARE VERSION 5.2.
1. HIN-0297-40272
Two problems were discovered with the QA functions for the Autopsy
Accession Area.
# 1: The user wasn't prompted to enter any QA codes while
executing the option QA codes entry/edit [LRAPQACD] and
choosing the Autopsy Accession Area.
# 2: When using the option QA outcome review cases [LRAPQOR], not
all of the information was printing. Prior to patch LR*5.2*72,
the actual Autopsy accession # and date of autopsy would print
on the 2nd part of the report.
2. It was reported that after patch LR*5.2*72 that the report format
for Autopsy data review [LRAPAURV] did not accommodate the new
Reporting Site: Hines, Long Beach
accession # format.
ROUTINE SUMMARY:
=================
The second line of the routine now looks like:
<tab> ;;5.2;LAB SERVICE;**[patch list]**; Sep 27, 1994
Checksum Values
Routine Name Before Patch After Patch Patch List
============ ============ =========== ==========
LRAPQACD 1985498 1982867 72,85,155
LRAPQOR2 5647114 5107599 155
LRAURV 8143951 8364694 155
Installation Instructions:
=================
Test Site(s) Hines, Madison, Long Beach
1. Use the 'INSTALL/CHECK MESSAGE' option on the PackMan menu. This
option will load the KIDS package in this message onto your system.
2. From the 'Installation Menu' of the KIDS menu, run the option
'Verify Checksums in Transport Global' and verify that all routines
have the correct checksum.
3. From the 'Installation Menu' of the KIDS menu, you may use the option
'Print Transport Global' to view what will be installed on your
system prior to the Install.
4. Review your mapped set. If the routines are mapped, they should
be removed from the mapped set at this time.
5. Users can remain on the system. Patch installation should take less
than 5 minutes. No options need to be placed out of service.
Install during non-peak times.
6. From the 'Installation Menu' of the KIDS menu, run the option
'Install Package(s)' Select the package LR*5.2*155 and proceed with
DESCRIPTION:
install.
7. If any routines were unmapped as part of step 4, they should be
returned to the mapped set once the installation has run to
completion.
Below is an example of the dialogue seen during the KIDS load.
Select Installation Option: INStall Package(s)
============
Select INSTALL NAME: LR*5.2*155 Loaded from Distribution
3/26/98@13:49
:39
=> LR*5.2*155
This Distribution was loaded on Mar 26, 1998@13:49:39 with header of
LR*5.2*155
It consisted of the following Install(s):
LR*5.2*155
LR*5.2*155
Install Questions for LR*5.2*155
Want to DISABLE Scheduled Options, Menu Options, and Protocols? YES// NO
Enter the Device you want to print the Install messages.
You can queue the install by enter a 'Q' at the device prompt.
Enter a '^' to abort the install.
|