| DESCRIPTION OF ENHANCEMENTS |
This patch contains a new option [SR BLOOD PRODUCT VERIFICATION] within
selected product is not associated with the patient identified, the
warning message will be displayed.
A new option called [SR BLOOD PRODUCT VERIFY AUDIT] is included to allow
auditing of the option above. It has been placed on the "Chief of Surgery
Menu" on the "Management Reports Menu".
After installing this patch, IRM needs to turn on the KERNEL Audit Option
by invoking the option, [XUAUDIT] for the new option exported with this
patch [SR BLOOD PRODUCT VERIFICATION]. The expiration date for the audit
the VistA Surgery package which will be used for transfusion error risk
should be set to a date 100 years into the future.
management. The new option is contained on the Surgery "Operations Menu".
The option performs the following function; after scanning the blood unit
ID, the software will check for an association with the patient
identified. If there are multiple entries with the Unit ID scanned, these
entries will be listed along with the Blood Component, Patient
Associated, and Expiration Date. The user will then be prompted to select
the one that matches the blood product about to be administered. If the
|