A4A7*1.01*11 (1900)    BUILD (9.6)

Name Value
NAME A4A7*1.01*11
DATE DISTRIBUTED 1998-12-03 00:00:00
PACKAGE FILE LINK CAPACITY MANAGEMENT - RUM
TYPE SINGLE PACKAGE
DESCRIPTION OF ENHANCEMENTS
*************************************************************************
   Routine A4A7B to scan for references to files 3, 6, 16, 20.
   
3. The Scan routine A4A7B can be run after patch A4A7*1.01*11 has been
   installed/run looking for local references.
  
4. It also adds two fields into the New Person file that had been left out
   XUS Logon Atempt Count and XUS Active User.

Routine Summary
The following routines are included in this patch.  The second line of each
**** THIS PATCH WILL REMOVE THE DD AND DATA FOR FILES 3/6/16/20      ****
of these routines now looks like:
 ;;1.01;NEW PERSON;<patchlist>;2/9/96

                 Checksum
Routine         Old       New      2nd Line
A4A7KILL                2767871    **11**

Sites should use CHECK^XTSUMBLD to verify checksums

 =========================================================================
**** AND THE CROSS REFERENCES IN FILE 200 THAT SET DATA INTO THEM.   ****
Installation:
     
 1.  Use the 'INSTALL/CHECK MESSAGE' option on the PackMan menu. This
     option will load the KIDS package onto your system.
     
 2.   The patch has now been loaded into a Transport global on your
      system. You now need to use KIDS to install the Transport global.
      On the KIDS menu, under the 'Installation' menu, use the following
      options:
      
*************************************************************************
         Verify Checksum's in Transport Global
         Print Transport Global
         Compare Transport Global to Current System
         Backup a Transport Global
     
 3.   Inhibit users from login into the system.
      Also place TASKMAN in a wait state.

     
 4.  On the KIDS menu, under the 'Installation' menu, use the following

      option:
        Install Package(s)  'A4A7*1.01*11'
                             ============
        
 5.  With the user's still off the system:
 
DO K^A4A7KILL
Are you sure you want to kill off files 3, 6, 16, 20:? NO// YES
Deleting file 20
Deleting file 6
1. It also will delete 2 fields from file 49 (SERVICE/SECTION).
Deleting file 16
Deleting file 3

... more stuff printed out

DONE

 6.  Enable user's login.
     Remove TASKMAN from the wait state.
     You can now delete the A4A7KILL routine.
  Fields 7 & 8 (subfiles 49.02 and 49.03) were deleted (DD's and data).
 =========================================================================

  
2. A reminder to be sure that you have run the A4A7*1.01*9 patch,
TRACK PACKAGE NATIONALLY YES
FILE
  • DD NUMBER:
    • NEW PERSON (File-top level)
      FIELD NUMBER:
      • XUS Logon Atempt Count
      • XUS Active User
    UPDATE THE DATA DICTIONARY:   YES
    SEND SECURITY CODE:   NO
    SEND FULL OR PARTIAL DD:   PARTIAL
    DATA COMES WITH FILE:   NO
BUILD COMPONENTS
  • ENTRIES:
    • A4A7KILL
      ACTION:   SEND TO SITE
      CHECKSUM:   B8914377