| DESCRIPTION OF ENHANCEMENTS |
1. Several sites have reported a problem related to medication orders
DFN of the patient in the pending order being updated. This should keep
the problem from occurring.
2. A site reported a problem with an undefined error when attempting to
process an order. This patch is to correct the program to prevent the
undefined error. NOIS: BRX-0200-10119.
getting mixed up. The problem most frequently reported is that a Unit
Dose order is being changed to an IV order. The development team has been
unable to recreate this problem, but thinks the problem may be a result of
using the variable DFN in the PSJHL messaging routines. With the
installation of this patch the variable DFN will be changed to PSJHLDFN in
the PSJHL messaging routines. Additionally checks have been added to PSJOE
and PSJLIFN to be sure that the order number being finished is the order
number being updated and that the DFN of the patient selected matches the
|