DESCRIPTION OF ENHANCEMENTS |
MSG from Warren Wright about large numbers of DEVICE LOCK bulletins
The check to close hung SPOOL documents had a incorrect test.
ZTMON1 7519989 ;;8.0;KERNEL;**36**;Jul 10, 1995
ZTMS 5200197 ;;8.0;KERNEL;**2,18,24,36**;Jul 10, 1995
ZTMS1 6210144 ;;8.0;KERNEL;**36**;JUL 10, 1995
ZTMS2 5283853 ;;8.0;KERNEL;**2,18,23,36**;Jul 10, 1995
ZTMS3 9454395 ;;8.0;KERNEL;**1,18,36**;Jul 03, 1995
=========================================================================
INSTALLATION:
1. Some of these routines are usually mapped on systems that allow
mapping, so you will need to disable mapping for the affected routines.
2. Use the 'INSTALL/CHECK MESSAGE' option on the PackMan menu. This
option will load the KIDS package onto your system.
3. The patch has now been loaded into a Transport global on your system.
You now need to use KIDS to install the Transport global.
On the KIDS menu, under the 'Installation' menu, use the following
options:
Verify Checksums in Transport Global
Print Transport Global
NOIS SEP-0796-62056 The purge option was failing to get any site data
Compare Transport Global to Current System
Backup a Transport Global
4. Users can remain on the system.
Also STOP TASKMAN. As long running jobs exit, they will get CLOBER errors.
This isn't a problem because they have finished their work and TaskMan
will start new ones.
5. On the KIDS menu, under the 'Installation' menu, use the following
options:
from the Kernel System Parameter file. It was looking at the wrong node.
Install Package(s) 'XU*8.0*36'
6. MSM Sites - Answer YES to the question 'Want to MOVE routines to other
CPUs?'. Enter the names of your Compute and Print server(s).
7. After installing this patch, you need to move several routines from
your production account to the manager account:
ZIS4MSM
ZIS4VXD
ZISC
ZISHMSM
ZISHVXD
ZISTCP
ZTER
ZTER1
ZTM
ZTM0
ZTM5
ZTMGRSET
NOIS NOL-0796-70230 If the data in the spool file was longer that 255
ZTMON1
ZTMS
ZTMS1
ZTMS2
ZTMS3
and in the manager account, rename:
DO RELOAD^ZTMGRSET
Select the System
characters, it would cause an error in %ZIS4 on DSM systems. This has
Patch number to load: 36
8. AXP Sites, after patch has installed, rebuild your map set.
9. Start TaskMan, Restart Taskman on other nodes if you need to run more
than one TaskMan.
been fixed but the report may not print the way it would have if sent
directly to the printer.
sent when someone leans on keyboard.
NOIS WBP-0796-20862 When the number of spool documents is checked, only
those with data are counted. This is changed to count all spool documents
with or without data.
E3R -- Request for a way to have the current date as part of a auto
generated name (GENERATE SPL DOC NAME). Now if the device name includes
"|DT|" that string will be replaced with the current date.
E3R 8844 To include Person class in the User Inquiry.
NOIS IVM-1095-32452 Some times taskman doesn't release devices
when it should.
NOIS NOL-0996-70063 At a dual TaskMan site Problem starting tasks on
the working node. The TaskMan part of this patch was developed to address
problems at dual TaskMan sites after the install of patch 24. It is
unclear exactly what the problem was, but with load balancing work would
back up. There is a new algorithm to start new submanagers and when
submanagers should exit. We try and keep the number of submanagers at a
level equal to a: the number of devices in the IO list. b: the MIN
NOIS MCM-1195-51490 That the DEVICE LOCK bulletins aren't much help.
SUBMANAGER CNT. All submanagers will remain if the JOB list has any tasks
in it.
----- This patch adds two new fields to the TaskMan site
parameter file (14.7): (1), MIN SUBMANAGER CNT, allows a site to set a
lower limit on the number of submanagers to keep around. (2), TM MASTER,
is only used when a volume set is mounted on another but shares the
library account. This is a pointer back to file 14.7 and would point to
the entry that is the control entry for TaskMan on that node.
Local MSG #1082921
DIC error in Add a New User. Problem in the page numbering of the
new FORM for Add a New User and SECONDARY MENUS. Sending out all three
FORMs with unified page numbering.
NOIS MAD-0895-40177 Some sites have some leftover nodes in the Institution
file.
Collect more data in the standard error trap.
NOIS CLE-1095-43605 The check if a user needed to be deactivated was
In patch 24 $X was set to zero before doing the close execute code.
This was changed to check if $X>0 and to set it to 1 so that code (like
P-MESSAGE) that test $X would still work.
If some package was installed after Kernel 8, the "ID" nodes on the
NEW PERSON file got changed back to an early version. Nodes are reset.
NOIS IND-0996-41382 Changes to FTG^%ZISH made in XU*8*24 didn't work for
input like S Y=$$FTG^%ZISH("","TEST.DAT",$NA(OUT(0)),1) it did work
counting 'Keep at Terminate' keys even though they would never be removed.
fine on S Y=$$FTG^%ZISH("","TEST.DAT",$NA(^TMP("XX",$J,0)),3). Fixed.
Various requests to bring back ZTMGRSET. This new version will load all
all routines if called from the top, or only the routines with a given
patch number if called at RELOAD^ZTMGRSET.
NOIS BRK-1096-12512, CHW-0996-42161 While testing changes to %ZTER for
use with the new error trap we got ECODE errors under some conditions.
This has been fixed with a small change to %ZTER.
Routine CheckSum 2nd Line
XUINPCH 1467475 ;;8.0;;KERNEL;**20,36**;Feb. 9, 1996
XUSTERM 14380010 ;;8.0;KERNEL;**36**;Jul 10, 1995
XUSTZ 3010944 ;;8.0;KERNEL;**36**;Jul 10, 1995
XUTMUSE2 13026855 ;;8.0;KERNEL;**36**;Jul 10, 1995
ZIS3 6450084 ;;8.0;KERNEL;**18,36**;JUL 10, 1995
ZIS4MSM 6649854 ;;8.0;KERNEL;**23,36**;JUL 03, 1995
ZIS4VXD 8342152 ;;8.0;KERNEL;**23,36**;JUL 03, 1995
ZISC 8463272 ;;8.0;KERNEL;**24,36**;JUL 10, 1995
ZISHMSM 5354551 ;;8.0;KERNEL;**24,36**;JUL 10, 1995
NOIS MAC-0696-61616 WBP-1195-20971 CTX-0896-71639
ZISHVXD 7245146 ;;8.0;KERNEL;**24,36**;JUL 10, 1995
ZISPL1 8550686 ;;8.0;KERNEL;**23,36**;Jul 10, 1995
ZISPL2 4088281 ;;8.0;KERNEL;**23,36**;Jul 10, 1995
ZISTCP 1828160 ;;8.0;KERNEL;**36**;Jun 02, 1994
ZTER 18736553 ;;8.0;KERNEL;**8,18,32,24,36**;JUL 10, 1995
ZTER1 5603505 ;;8.0;KERNEL;**18,24,36**;JUL 10, 1995
ZTM 7805017 ;;8.0;KERNEL;**24,36**;JUL 10, 1995
ZTM0 5563711 ;;8.0;KERNEL;**42,36**;JUL 10, 1995
ZTM5 3748675 ;;8.0;KERNEL;**24,36**;JUL 10, 1995
ZTMGRSET 12724965 ;;8.0;KERNEL;**36**;Dec 30, 1993
|