DI*21.0*36 (373)    BUILD (9.6)

Name Value
NAME DI*21.0*36
PACKAGE FILE LINK VA FILEMAN
TYPE SINGLE PACKAGE
DESCRIPTION OF ENHANCEMENTS
This patch fixes a bug in ^DIWP that started after patch DI*21*33: 
 
         MSM Sites - Restart Taskman.  
 
    12.  Enable users' login.  
The related NOIS Calls are: WPB-1296-31219 and NOP-1296-11296.
 
This patch reverses the fix sent by patch 33.
                                                                           
 Routine Summary: 
 ================
  The following routines are included in this patch.  The second line of
these routines now look like:
                               
                  
  <tab>;;21.0;VA FileMan;**
 
 Routine Summary: 
 ================
  The following routines are included in this patch.  The second line of
these routines now look like:
  
  <tab>;;21.0;VA FileMan;**[patch list]**;Dec 28, 1994 
  
  CHECK^XTSUMBLD results: 
Applications doing the following are affected by this bug::
  
  Routine Name   Before Patch    After Patch     Patch List 
  ============   ============    ===========     ==========
  DIWP           5150036         5103576         33,36
 
 Installation Instructions: 
 ==========================
  
    1.  The routines DIW* are usually mapped on systems that allow
mapping.  Alpha sites that use routine mapping will need to disable
              
mapping for these routines.
 
    2.  Use the 'INSTALL/CHECK MESSAGE' option on the PackMan menu. This
option will load the KIDS package onto your system.  The environment check
routine DIENV will run automatically.
 
    The Environment Check routine, DIENV, is sent in order to prevent the
inadvertent queueing of the installation of this patch.
 
    3.  The patch has now been loaded into a transport global on your
       1.  Application calls ^DIWP with DIWL=0.
system. You now need to use KIDS to install the transport global.
 
    4.  On the KIDS menu, under the 'Installation' menu, use the following
options: 
           Print Transport Global 
           Compare Transport Global to Current System 
           Verify Checksums in Transport Global 
           Backup a Transport Global 
 
    5.  Inhibit users from login into the system.  If users stay on the
                                       
system while installing this patch, a hard error may occur while word
processing fields are printed or edited.
 
    6.  AXP Sites - Place Taskman in a WAIT State.  
        MSM Sites - STOP Taskman.  
 
    7.  On the KIDS menu, under the 'Installation' menu, use the following
option: 
           Select Installation Option:  Install Package(s)
           Select INSTALL NAME: DI*21.0*36
       2.  After the call to ^DIWP, application resets DIWL=0 and then
                                ==========
 
           Answer 'NO' to 'Want to DISABLE Scheduled Options, Menu
Options, and Protocols?
 
    8.  MSM Sites - Answer YES to the question 'Want to MOVE routines to
other CPUs?'.
    Then enter the names of your other Compute and Print server(s).  
    NOTE: You will then see the following message: 
       TASKMAN is not running. You must run the routine XPDCPU in the 
accesses the ^UTILITY global.  No text is found when referencing
production UCI for each of the VOLUME SETS you have listed once the 
installation starts!! 
 
    9.  MSM Sites - After the installation begins, you will be prompted to
enter a DEVICE.  After the device has been entered, KIDS will pause.  At
this time, you need to go to each of the CPUs that were entered in step 8,
and start a job that will allow them to receive the patched routines.  On
each one, you do the following:
    a) >D ^XUP    This will set up the programming environment.  
        ======
^UTILITY($J,"W",DIWL.
    b) >D ^XPDCPU  This starts the job that receives the patched routines.
        =========
    c) Select INSTALL NAME: DI*21.0*36
                            ==========
The installation will then continue.  
 
    10.  AXP Sites - After the patch has been installed, rebuild your map
set. 
 
    11.  AXP Sites - Remove Taskman from WAIT State.  
TRACK PACKAGE NATIONALLY NO
BUILD COMPONENTS
  • ENTRIES:
    • DIWP
      ACTION:   SEND TO SITE
      CHECKSUM:   B8710902
ENVIRONMENT CHECK ROUTINE DIENV