Problem:
In some instances, the right node does not exist, causing the
error to be generated.
Resolution:
The solution is to check for the existence of the right node. If it does
not exist, the program bypasses the line of code without error.
When the Automatic Pharmacy Statistics [PSU PBM AUTO] option extract is
run,
the following error is generated:
<UNDEFINED>COMVAR+2
S PSUSIG=$P( ^TMP("PSOR",$J,PSURXIEN,"SIG",1,0),U,1)
|