| DESCRIPTION OF ENHANCEMENTS |
************************************************************************
INSTALLATION INSTRUCTIONS
=========================
The install time for this patch is less than 2 minutes. This patch
can be installed when Laboratory users are on the system.
Suggested time to install: Off peak hours.
The install will disable a Lab option as specified in #7 below.
1. When using the option Link Result NLT Manual [LR7O MAN RESULT NLT] the
NOTE: Kernel patches must be current on the target system
to avoid problems loading and/or installing this patch.
Patch installation needs to be coordinated with the Laboratory
Information Manager (LIM/ADPAC).
1. If any of the above routines are mapped, disable mapping for them.
option was exiting the user to the Kernel menu system after mapping a
2. Use the 'INSTALL/CHECK MESSAGE' option of the PackMan menu. This
option will load the KIDS patch onto your system.
3. The patch has now been loaded into a Transport global on your
system. You now need to use KIDS to install the transport global.
4. On the 'Kernel Installation & Distribution System' Menu (KIDS),
select the 'Installation' menu.
5. Use the 'Verify Checksum in Transport Global' option and verify that
single test. This resulted in a user answering the option prompts for
all routines have the correct checksums.
6. On the KIDS menu, under the 'Installation' menu, use the following
options:
Print Transport Global
Compare Transport Global to Current System
Backup a Transport Global
If you wish to preserve a copy of the routines exported in this
patch prior to installation, you should use the 'Backup a Transport
each test to be mapped. This patch will change the option dialog to
Global' option at this time. You may also compare the routines in
your production account to the routines in the patch by using the
'Compare a Transport Global to Current System' option.
7. The install will disable the following Lab option during patch
installation.
Link Result NLT Manual [LR7O MAN RESULT NLT]
8. Use the 'Install Package(s)' option under the 'Installation' menu
allow the user to select and map multiple tests after answering the
and select the package 'LR*5.2*280'.
When prompted ' Want KIDS to Rebuild Menu Trees Upon Completion of
Install? YES//' choose 'NO'.
Want KIDS to INHIBIT LOGONs during the install? YES// NO
When prompted 'Want to DISABLE Scheduled Options, Menu Options, and
Protocols? YES//', choose 'NO'.
option prompts. To exit or abort from the option the user should enter
9. On a mapped system, rebuild your map set.
10. Routine LR280 will be deleted after successful patch installation.
POST-INSTALLATION INSTRUCTIONS:
===============================
None
a "^" which will return the user to the Kernel menu system.
************************************************************************
Installation example:
Select Installation Option: INStall Package(s)
Select INSTALL NAME: LR*5.2*280
Loaded from Distribution 12/20/01@10:27:28
=> LR*5.2*280
This Distribution was loaded on Dec 20, 2001@10:27:28 with header of
LR*5.2*280
NOIS DAY-1101-42242 and HWH-1101-42338
It consisted of the following Install(s):
LR*5.2*280
Checking Install for Package LR*5.2*280
Will first run the Environment Check Routine, LR280
Sending install started alert to mail group G.LMI
--- Environment Check is Ok ---
Install Questions for LR*5.2*280
Incoming Files:
60 LABORATORY TEST (Partial Definition)
Note: You already have the 'LABORATORY TEST' File.
64 WKLD CODE (Partial Definition)
VISTA Laboratory Package patch LR*5.2*280 contains no changes to software
2. FileMan inquires in to files LABORATORY TEST (#60) and WKLD CODE (#64)
Note: You already have the 'WKLD CODE' File.
Want KIDS to Rebuild Menu Trees Upon Completion of Install? YES// NO
Want KIDS to INHIBIT LOGONs during the install? YES// NO
Want to DISABLE Scheduled Options, Menu Options, and Protocols? YES// NO
Enter the Device you want to print the Install messages.
You can queue the install by enter a 'Q' at the device prompt.
was not displaying the check sum digit for all LOINC codes. An output
Enter a '^' to abort the install.
DEVICE: HOME// TELNET
Install Started for LR*5.2*280 :
Dec 20, 2001@11:45:16
Build Distribution Date: Dec 12, 2001
transform has been added to include the check digit with the LOINC code.
Installing Routines:
Dec 20, 2001@11:45:16
Running Pre-Install Routine: PRE^LR280
*** Pre install started ***
*** No action required ***
*** Pre install completed ***
Installing Data Dictionaries:
Dec 20, 2001@11:45:17
Installing PACKAGE COMPONENTS:
Installing OPTION
Dec 20, 2001@11:45:17
3. In the LABORATORY TEST (#60) file, subfile SITE/SPECIMEN (#100), LOINC
LR*5.2*280
Running Post-Install Routine: POST^LR280
*** Post install started ***
*** No action required ***
*** Post install completed ***
CODE (#95.3) field was not being updated for atomic 'CH' subscript tests.
Sending install completion alert to mail group G.LMI
Updating Routine file...
Updating KIDS files...
LR*5.2*280 Installed.
Dec 20, 2001@11:45:17
This has been corrected. It has been reported that the zero node of
Install Message sent #XXXXX
Install Completed
SITE/SPECIMEN field do not exist. This patch will create the zero node if
required during mapping.
SPO-120-50468
controlled by VHA DIRECTIVE 99-053, titled VISTA BLOOD BANK SOFTWARE.
4. During patch development/software review the following defects were
identified and corrected.
A. In the option Result NLT Auto Linker [LR7O AUTO RESULT NLT] if
a user requested printing of a List of Result NLT Linked Codes
and device selection was unsuccessful or aborted then the Kernel IO*
variables were not being restored to the user's home device. This
patch will now call HOME^%ZIS when device selection is unsuccessful
or aborted by the user to restore the user's home device settings.
B. If a user selects the semi-auto method of linking, the option was
exiting the user from the option when a Result NLT was not selected
and mapped to an entry in the LABORATORY TEST file (#60). This patch
will allow the user to continue mapping tests. To exit or abort from
the option the user should enter a "^" which will return the user to
the Kernel menu system.
C. The entry in LABORATORY TEST file (#60) was only being locked
when using the manual method of linking. The Semi-auto method was
not locking the file. This patch will lock the entry being edited
in LABORATORY TEST file (#60) when either method is selected.
5. When mapping certain LOINC codes a FileMan error of 'undefined
variable ^(4) is' generated because of the lookup screen. This error
has been corrected.
SHR-1201-70505
ASSOCIATED NOIS
This patch will address fixes to defects reported in NOIS DAY-1101-42242
---------------
DAY-1101-42242
HWH-1101-42338
SHR-1201-70505
SPO-1201-50468
MAR-1201-21794
ASSOCIATED E3R'S
----------------
None
and HWH-1101-42338 when using the option Link Result NLT Manual [LR7O MAN
TEST SITES
----------
Dayton VAMC
Heartland-West HCS
Milwaukee VAMC
Shreveport VAMC
Durham VAMC
Long Beach VAMC
RESULT NLT] to map result NLT codes to a site's LABORATORY TEST file
ROUTINE SUMMARY
===============
The following routines are included in this patch. The second line
of each of these routines now looks like:
<tab> ;;5.2;LAB SERVICE;<patchlist>;Sep 27, 1994
Checksum Checksum
Routine Name Before Patch After Patch Patch List
------------ ------------ ----------- ------------
(#60).
LR280 N/A 4831435 280 (Deleted by KIDS)
LR7OU641 12410597 12157260 153,201,278,280
LRLNC0 14797379 15016901 215,232,278,280
LRLNCC 2637694 2634007 232,280
LRLNCMD 6826367 6815286 232,278,280
List of preceding patches: 232,278