| DESCRIPTION OF ENHANCEMENTS |
1. A site reported receiving an error when attempting to print a
editing the original order, not the newly copied order. This patch
corrects the problem by preserving the original order's dispense drug.
NOIS# ANN-1201-40453
3. A site reported a problem when running the Patients on Specific
Drug(s) [PSJ PDV] option and selecting List by (O)rderable Item. The
Inactive Date for the Orderable Item was no longer being displayed as an
identifier. This patch corrects this problem. NOIS# PAL-1101-62555.
4. A site reported a problem with the Pick List [PSJU PL] option. After
Medication Administration Record (MAR) for an IV order that contained
installing the Pharmacy Ordering Enhancements, each order's Special
Instructions no longer appear on the Pick List. This patch corrects the
problem by displaying the Special Instructions on the Pick List.
NOIS# WRJ-1201-11762.
5. A site reported a problem with the stop date calculation when
finishing IV orders. The stop date for the one-time orders was being
used for all following orders. This patch corrects this problem by
excluding one-time orders from the stop date calculation when the IV site
parameter specifies that all orders should have the same stop date.
administration times. This patch corrects this problem by modifying MAR
NOIS# SAG-1201-40283.
6. A site reported a problem with the editing of an order's dispense drug.
Multiple dispense drugs can be added to the order, but the ability to edit
or delete incorrect dispense drugs no longer exists. This patch corrects
this problem by allowing dispense drugs to be edited and deleted.
NOIS# UNY-1001-12315.
7. If a pending order can be finished as either Unit Dose or IV, user
with the PSJ RNFINISH key can't finish the order as Unit Dose. This
print to ignore administration times for IV orders, unless they are
patch will allow the nurses to finish Inpatient Med orders as Unit Dose
orders. NOIS: BHH-0102-40058.
Piggyback, Chemotherapy Piggyback or Intermittent Syringe orders.
NOIS# CLE-0901-41216
2. A site reported receiving an error when attempting to edit an order
immediately after copying it to a new order. The error only occurs when
|