| DESCRIPTION OF ENHANCEMENTS |
1. Problem: When a medication was given and then not given the Gui did
to the log file, which caused BCMA to shut down.
Corrective Action: Additional error trapping was added to report the
error to the user without shutting down.
3. Problem: When attempting to mark multiple patches as removed, the user
receives the following error message:
"Error(s) Filing Transaction MEDPASS"
Business Logic Error: PRN Medications MUST Have a PRN Reason
not validate.
Business Logic Error: PRN Orders cannot be marked NOT Given
Corrective Action: BCMA GUI has been modified to not allow the
multiple marking of patches as removed.
4. Problem: User was receiving an undefined variable error in routine
PSBVDLU1 when attempting to log on to the BCMA GUI application.
Corrective Action: The code was modified to not error when logging on
to the GUI application.
5. Problem: When using the CPRS Med Order button, the IV Fluid Order
screen is not displaying the same volume as the BCMA Order Manager
screen.
Corrective Action: The IV Fluid Order screen is now displaying the
same volume as the BCMA Order Manager screen.
6. Problem: The user would recieve an error when trying to launch
multiple copies of the BCMA GUI.
Corrective Action:The GUI will validate when a user marks a med from
Corrective Action: The GUI has been corrected to display the
Open Error message, "There is already one copy of Bar Code
Medication Administration running on this machine!"
7. Problem: When launching the BCMA Site Parameters application, the focus
was not on the electronic signature box.
Corrective Action: The BCMA Site Parameters application has been
modified to place focus on the electronic signature box.
Given to Not Given that the user either has the "PSB MANAGER" key or
8. Problem: One-time orders were printing on the Due List [PSBO DL]
option after the stop date of the order.
Corrective Action: The printed Due List [PSBO DL] option was modified
to not print one-time orders past the stop date of the order.
that the user id matches the user id that made the entry in the med
log.
2. Problem: An error would occur if the user did not have write access
|