LR*5.2*288 (4549)    BUILD (9.6)

Name Value
NAME LR*5.2*288
DATE DISTRIBUTED 2002-07-18 00:00:00
PACKAGE FILE LINK LAB SERVICE
TYPE SINGLE PACKAGE
DESCRIPTION OF ENHANCEMENTS
This patch is being released in support of the VBECS (Vista Blood 
                      exists (XTRCT^GMTSLRTE).  The new API will pass
               Compare Transport Global to Current System
               Verify Checksums in Transport Global
               Backup a Transport Global
        4. Users may remain on the system.
        5. No options need to be placed out of service.
        6. Installation time is less than 2 minutes during off peak
           hours and less the 5 minutes during peak hours.
        7. Installation of this patch requires no additional memory
           space.
        8. From the 'Installation Menu' of the KIDS menu, run the
                      the DFN, the TMP subscript location, the inverse
           option 'Install Package(s)' Select the package 'LR*5.2*288'
           and proceed with the install.
        9. If any routines were unmapped as part of step 2, they should
           be returned to the mapped set once the installation has run
           to completion.
                      end and inverse beginning date of search in a
                      call to the existing routine.
 
 Get All Available Units
      AVUNIT^VBECA4   This API will be a shell to an API that already
                      exists (XTRCT^GMTSLRBE).  The new API will pass
                      the DFN, the TMP subscript location, the inverse
                      end and beginning date, and the max number of
Establishment Computer Software) Blood Bank Modernization Project.  In 
                      records in a call to the existing routine.
 
 Blood Product Lookup for Surgery
      ^VBECA5A        The VBECA5A API has been created to allow the
                      Surgery package to convert the existing pointer
                      fields  used to list available Blood Products
                      contained in the Blood Product file (#66), with a
                      free text field.  The transition of the Blood
                      Bank system from the existing M based system to a
                      .NET/SQL based system will eliminate the ability
the future, data will be transitioned from the existing M database to a 
                      of the Surgery package to access the Blood Product
                      data using the current method.
 
 EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*288 does not 
contain any changes to the VISTA BLOOD BANK Software as defined by VHA 
DIRECTIVE 99-053 titled VISTA BLOOD BANK SOFTWARE VERSION 5.2.
 
 EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*288 does not 
alter or modify any software design safeguards or safety critical 
elements functions.
Microsoft SQL database.  The API's release in this patch will allow the 
 
 RISK ANALYSIS: Changes made by patch LR*5.2*288 have no effect on Blood 
Bank software functionality, therefore RISK is none.
 
 DBIA: 3176-A
       3176-B
       3631
 
 Reference NOIS:   None
 
Health Summary and Surgery packages to transition to the new database 
 Reporting Site:   None
  
 Test Site(s):     Beckley, WV
                   Durham, NC
                   Puget Sound HCS
                   San Diego, CA
 
  
ROUTINE SUMMARY
===============
when it is released.
  The following routines are included in this patch.  The second line
  of each of these routines now looks like:
  <tab> ;;0.5;VBECS;<patchlist>;APR 26, 2002
 
                    Checksum       Checksum
   Routine Name     Before Patch   After Patch    Patch List
   ------------     ------------   -----------    ------------
   VBECA4           NEW            4083168        288
   VBECA5A          NEW            790890         288
 
 
List of preceding patches: None
Sites should use CHECK^XTSUMBLD to verify checksums.
 
  Installation Instructions:
  ==========================
 
  NOTE: This KIDS install does not place any options out of service
        during the install and no user options are affected.
        If KIDS prompts:
  
 Get Transfusion Data
        "Want KIDS to Rebuild Menu Trees Upon Completion of
         Install? YES// NO"
        "Want KIDS to INHIBIT LOGONs during the install? YES// NO"
        "Want to DISABLE Scheduled Options, Menu Options, and
        Protocols? YES// NO"
 
        The site should answer "NO" to all three questions.
            Note: You may not receive all three prompts at your site.  
  
        1. Use the 'INSTALL/CHECK MESSAGE' option on the PackMan menu.
      TRAN^VBECA4     This API will be a shell to an API that already
           This option will load the KIDS package in this message onto
           your system.
        2. Review your mapped set.  If the routines are mapped, they
           should be removed from the mapped set at this time.
        3. The patch has now been loaded into a Transport global on
           your system. You now need to use KIDS to install the
           Transport global.
           On the KIDS menu, under the 'Installation' menu, use the 
           following options:
               Print Transport Global
TRACK PACKAGE NATIONALLY YES
BUILD COMPONENTS
  • ENTRIES:
    • VBECA4
      ACTION:   SEND TO SITE
      CHECKSUM:   B9746447
    • VBECA5A
      ACTION:   SEND TO SITE
      CHECKSUM:   B1674894