PSB*2.0*10 (4569)    BUILD (9.6)

Name Value
NAME PSB*2.0*10
DATE DISTRIBUTED 2002-11-14 00:00:00
PACKAGE FILE LINK BAR CODE MED ADMIN
TYPE SINGLE PACKAGE
DESCRIPTION OF ENHANCEMENTS
 Patch Description:
 Corrective Action: The BCMA Print Label [PSBO BL] option was modified to 
 perform the drug validate process before the device selection process.  
 Therefore, the drug validation process will be performed if the system 
 device was set to BROWSER or queued to a device.
 
 Problem: In reference to the BCMA Print Label [PSBO BL] option, a problem
 was discovered in the coding logic that created an entry in the BCMA 
 Report Request file (#53.69).  If the user canceled the label print 
 process as a result of a mismatch between the selected drug and patient, 
 an impartial or bogus entry would remain in the BCMA Report Request file 
 ================= 
 (#53.69) occupying vital system resources. 
 
 Corrective Action: The BCMA Print Label [PSBO BL] option was modified by 
 inserting the necessary coding logic to delete the impartial or bogus 
 entry in the BCMA Report Request file (#53.69) when the print label 
 procedure is cancelled as a result of a mismatch between the selected 
 drug and patient.
 
 Problem: In reference to the BCMA Print Label [PSBO BL] option, a problem
 was discovered in the ScreenMan data input functions.  If the selected 
 
 patient requires a Means Test, the option will abruptly display a message
 to the user indicating "*** Patient Requires a Means Test ***" and the 
 ScreenMan data input process was rearranged out of order.
 
 Corrective Action: The BCMA Print Label [PSBO BL] option was modified by 
 inserting the necessary coding logic to refresh the ScreenMan data input 
 screen when the Means Test notification message rearranged the data input
 process.  By refreshing the screen, the data input flow will return to 
 the next data input field.
 
 Problem: In reference to the BCMA Print Label [PSBO BL] option, a problem
 Problem: In reference to the BCMA Print Label [PSBO BL] option, a problem
 was discovered in the coding logic used to set a variable that contained 
 the internal entry number of the selected drug.  This problem was not 
 discovered in the initial release of BCMA V 2.0.
 
 Corrective Action:  The BCMA Print Label [PSBO BL] option was modified by
 inserting the correct coding logic to extract and store the selected drug
 internal entry number in the proper variable.
 
 Problem: In reference to the BCMA Print Label [PSBO BL] option, a problem
 was discovered in the drug validation process used to compare the 
 was discovered in the drug validation process used to check the patient 
 medication orders. The option only validated medication orders that were 
 classified a Unit Dose and it did not validate medication orders that 
 were classified as IV orders containing IV Additives and IV Solutions.
 
 Corrective Action:  The BCMA Print Label [PSBO BL] option was modified 
 by inserting the proper coding logic to validate IV orders that contained
 IV Additives and IV Solutions.
 selected drug with medication orders listed for the patient. The drug 
 validate process was performed only if the system device was set to 
 BROWSER or the user device.
 
TRACK PACKAGE NATIONALLY YES
BUILD COMPONENTS
  • ENTRIES:
    • PSBO
      ACTION:   SEND TO SITE
      CHECKSUM:   B65795979