| DESCRIPTION OF ENHANCEMENTS |
Problem: If there is a continuous order, with an admin times, and
corrections.
If a DUE LIST ERROR message is encountered with a Reason of "Invalid
frequency received from order" please do the following.
1. Determine if the schedule listed in the mail message is in FILE# 51.1
the ADMINISTRATION SCHEDULE FILE.
a. If it is not, Log a NOIS.
b. If it is, determine if the TYPE OF SCHEDULE is CONTINUOUS.
i. If it is not, log a NOIS.
the frequency is null, the GUI Bar Code Medication Administration (BCMA)
ii. If it is, determine if the frequency is a valid number
greater than zero.
1. If it is, log a NOIS.
2. If it is not, correct the frequency.
does not display the order on the Virtual Due List (VDL) and a Due List
Error Notification message is not generated.
Corrective Action: BCMA will generate a Due List Error Notification
message for those continuous orders that contain a standard schedule
with admin times and no frequency. This can also occur to non-standard
Schedules. Pharmacy should review the problem order and make necessary
|