| DESCRIPTION OF ENHANCEMENTS |
Install both patches on to the Vista Server and the PSB*3*7
on to the Contingency Workstations as close together as
possible during non-peak times. Since the location of the
Pharmacy Orders "Admin Times" data has been changed
in the HL7 message you could see orders on the workstation
missing this data on orders updated due to transitions of data
during the installation of these patches. The missing data will
correct itself when that order is updated.
Once installed it is suggested that the sites review the
Contingency System reports. Any missing "Admin Times"
can be corrected by running the Single Patient Init
[PSB BCBU INIT SINGLE PT] option or the Workstation
can be re-initialized.
*****************************************************
1. A fix for the '&' delimiter problem with the admin times. The
admin times was moved to another Field of the HL7 message
in the pharmacy patch PSJ*5.0*123.
This patch compensates for the pharmacy change.
*******************Important Note********************
2. When a user was added, edited or terminated, BCMA Contingency
Software would be called and the user would be evaluated,
and if appropriate be transmitted to the BCMA Contingency
Workstations. This evaluation was not occurring correctly.
As a result, all users added, changed or terminated were being
transmitted to the workstations. An additional screen was added
to ensure that only the appropriate users accounts were
transmitted to the workstation.
3. When a user had multiple divisions defined under their user
account and the workstations were setup using the
multidivisional capability the users divisions were not
interpreted correctly. A bug was found in the code that
looped through the user's division multiple and was corrected.
4. The user Update portion of the BCMA Contingency was not checking
the status of the "PSB BKUP ONLINE" parameter. Additional code
was added to check for the status of the "PSB BKUP ONLINE"
Sites running the Bar Code Medication Administration (BCMA)
parameter. If the parameter is set to "NO" then no updates
will be transmitted to the workstation from the user portion
of the package.
Contingency Software must install this patch on all
Contingency workstations in addition to being installed
on to the Vista Server. This patch is being released in
conjunction with the Inpatient Pharmacy patch PSJ*5*123.
|