SR*3.0*134 (5895)    BUILD (9.6)

Name Value
NAME SR*3.0*134
DATE DISTRIBUTED 2004-12-09 00:00:00
PACKAGE FILE LINK SURGERY
REQUIRED BUILD
  • SR*3.0*135
    ACTION:   Don't install, remove global
TYPE SINGLE PACKAGE
ALPHA/BETA TESTING NO
DESCRIPTION OF ENHANCEMENTS
1. LOCKING OF SURGICAL CASES FOR EDITING
   signed while the case or a concurrent case is open for editing. If a
   case is locked and another user attempts to open the same case for
   editing, a message will appear on the screen indicating the name of the
   user that has the case locked. Likewise, if a user attempts to sign 
   the Nurse Intraoperative Report or the Anesthesia Report while the 
   case is open for editing, a message will appear on the screen 
   indicating the name of the user that has the case open for editing.
   
2. ALLOW CHART PRINT OUTSIDE MAS
   This patch modifies the software responsible for printing
   Patch SR*3*100 introduced locking of a surgical case when a user opens
   electronically signed surgery reports to honor the ALLOW CHART PRINT
   OUTSIDE MAS parameter defined in the TIU DOCUMENT PARAMETERS file
   (#8925.95). If this parameter is set to YES or is null, users will be
   allowed to choose between printing a work copy or a chart copy. If this
   parameter is set to NO, only users in MAS will be allowed to print a
   chart copy and all other users will be allowed to print a work copy
   only.
 
3. QUARTERLY REPORT ARRAY CLEANUP
   This patch updates the software that generates the Surgery Quarterly 
   the case for editing, allowing only one user at a time to edit the same
   Report to kill a variable array that may cause problems when the
   Surgery Quarterly Report is transmitted from multidivisional
   facilities.
 
4. DATE/TIME OUTPUT TRANSFORM CORRECTION
   This patch corrects the output transform used to display the external 
   format of several date/time fields modified by patch SR*3*125. Also, an
   update is made to the way admission, transfer and discharge date/times 
   are retrieved and stored for Surgery Risk Assessment.
 
   case. This patch alters how surgical cases are locked and allows
5. DOCUMENTATION ERROR CORRECTION
   The patch SR*3*100 documentation problem described in NOIS
   PUG-0604-51225 is corrected in documentation distributed with this
   patch.
 
6. FIELD DESCRIPTION UPDATE
   In the SURGERY file (#130), the CONGESTIVE HEART FAILURE field (#207) 
   field description is updated with the 2004 definition.
 
7. PATIENT NAME/ID ON CARDIAC ASSESSMENT PRINTOUT
   multiple users to open the same case for editing up until the time that
   This patch corrects a problem with the cardiac assessment printout in 
   which the patient ID is truncated if the patient's name is more than 
   16 characters in length.
 
8. NOIS SHR-0904-71756
   This patch corrects the problem described in NOIS SHR-0904-71756 so
   that the printer is closed after printing the assessment upon
   assessment completion.
 
9. CARDIAC TRANSMISSION UPDATE
   either the Nurse Intraoperative Report or the Anesthesia Report is
   The cardiac assessment transmission is modified by this patch to 
   update the formatting of the date of death, if present.
 
10. NOIS SBY-0904-31547
   Application of this patch prevents the problem described in NOIS
   SBY-0904-31547.
 
11. ATTENDING REQUIRED BEFORE COMPLETING CASE
   To prevent possible cosigner problems with the Operation Report and 
   the Procedure Report (Non-OR), this patch will require the attending 
   signed. When a user enters the function to sign either report and after
   surgeon/provider to be entered before the case can be completed. 
   
   When a user enters the TIME PAT OUT OR field (#.232) in the SURGERY 
   file (#130), to complete a surgical case, if the ATTEND SURGEON field 
   (#.164) is blank, the software will prompt the user to enter the 
   attending surgeon. For non-OR procedures, when a user enters the TIME 
   PROCEDURE ENDED field (#122), if the ATTEND PROVIDER field (#124) is 
   blank, the software will prompt the user to enter the attending 
   provider.
   
   either report is signed, the software will again allow only one user at
   If the SURGICAL RESIDENTS (Y/N) field (#33) in the SURGERY SITE 
   PARAMETERS file (#133) is set to NO, when a surgeon is entered in the 
   SURGEON field (#.14) in the SURGERY file (#130), the software will 
   enter the surgeon in the ATTEND SURGEON field (#.164). For non-OR 
   procedures, when the provider is entered in the PROVIDER field (#123), 
   the software will enter the provider in the ATTEND PROVIDER field 
   (#124).
   a time to open the case for editing. Neither report for a case can be
TRACK PACKAGE NATIONALLY YES
FILE
  • DD NUMBER:
    • SURGERY (File-top level)
      FIELD NUMBER:
      • SURGEON
      • ATTEND SURG
      • TIME PAT OUT OR
      • TIME PROCEDURE ENDED
      • PROVIDER
      • ATTEND PROVIDER
      • CONGESTIVE HEART FAILURE
    UPDATE THE DATA DICTIONARY:   YES
    SEND SECURITY CODE:   NO
    SEND FULL OR PARTIAL DD:   PARTIAL
    DATA COMES WITH FILE:   NO
    MAY USER OVERRIDE DATA UPDATE:   NO
BUILD COMPONENTS
  • ENTRIES:
    • SROAPIMS
      ACTION:   SEND TO SITE
      CHECKSUM:   B25648052
    • SROAPCA
      ACTION:   SEND TO SITE
      CHECKSUM:   B24951681
    • SROMENU
      ACTION:   SEND TO SITE
      CHECKSUM:   B18420095
    • SROACOM
      ACTION:   SEND TO SITE
      CHECKSUM:   B20479071
    • SROATCM1
      ACTION:   SEND TO SITE
      CHECKSUM:   B51308276
    • SROPLSTS
      ACTION:   SEND TO SITE
      CHECKSUM:   B21285954
    • SROLOCK
      ACTION:   SEND TO SITE
      CHECKSUM:   B16348635
    • SROUTL1
      ACTION:   SEND TO SITE
      CHECKSUM:   B3751692
    • SROXR1
      ACTION:   SEND TO SITE
      CHECKSUM:   B12767880
    • SRSKILL
      ACTION:   SEND TO SITE
      CHECKSUM:   B16840358
    • SROVAR
      ACTION:   SEND TO SITE
      CHECKSUM:   B31841040
    • SROAUTL
      ACTION:   SEND TO SITE
      CHECKSUM:   B37814933
    • SROESPR
      ACTION:   SEND TO SITE
      CHECKSUM:   B27974669
    • SROESUTL
      ACTION:   SEND TO SITE
      CHECKSUM:   B6409983
    • SROQ2
      ACTION:   SEND TO SITE
      CHECKSUM:   B32844306
    • SROUTL
      ACTION:   SEND TO SITE
      CHECKSUM:   B41567848
    • SROARPT
      ACTION:   SEND TO SITE
      CHECKSUM:   B46276819
    • SRONIN
      ACTION:   SEND TO SITE
      CHECKSUM:   B60628354