| DESCRIPTION OF ENHANCEMENTS |
1. When a provider enters an IV order and the Pharmacist finishes the
screen captures that the pharmacist was using lower case. The system
responded differently because of the lower case letters. The changes
included in this patch will cause the system to function equally for
upper and lower case letters in the standard VISTA operation.
order and tries to delete an additive and make changes in the solution
field the additive shows as deleted. When the order is accepted, the
order re-displays shows with the same additive that was deleted. This
correction makes the needed code changes so that the deleted additive
will actually be deleted as requested.
2. The pharmacist is unable to edit the solution field of a newly entered
TPN order. It was noted in the original NOIS report and supporting
|