| DESCRIPTION OF ENHANCEMENTS |
1. An undefined variable error occurs when an attempt is made to print a
is edited, administration times and schedule frequency from the new
schedule do not default into the copied order. This patch corrects this
issue by using the administration times and schedule frequency from the
newly entered schedule.
HD0000000102178
3. When changing an IV order's schedule from a continuous schedule to a
one-time schedule with no frequency defined in the ADMINISTRATION
SCHEDULE file (#51.1), the order's schedule interval is not updated,
resulting in the order's IV labels printing based on the frequency of
MAR label for a non-verified order. The error occurs when the software
the original schedule. For example, if an IV order's schedule is changed
from Q6H to ONCE, IV labels will continue to print based on the Q6H
schedule, or 4 labels per day. This patch will require an order's
schedule interval to be updated with the frequency from the new schedule.
HD0000000092412
attempts to retrieve clinic appointment information from the non-verified
order. Once the order is verified the MAR label prints without producing
the error. This patch corrects this issue by correctly processing
non-verified orders without appointment information.
HD0000000068851
2. Immediately after copying a unit dose order, if the order's schedule
|