RMPF*3.0*4 (9337)    BUILD (9.6)

Name Value
NAME RMPF*3.0*4
DATE DISTRIBUTED 2011-07-29 00:00:00
PACKAGE FILE LINK REMOTE ORDER/ENTRY SYSTEM
REQUIRED BUILD
  • RMPF*3.0*1
    ACTION:   Warning only
TYPE SINGLE PACKAGE
ALPHA/BETA TESTING NO
INSTALLATION MESSAGE NO
PACKAGE NAMESPACE OR PREFIX
  • RMPF
DESCRIPTION OF ENHANCEMENTS
 
1. As approved by the PSAS Program Office, all Veteran eligibility 
 
 2. RMPFRPC1 - DDC changed to DALC. Added check to see if running from a
    production account. Comments were added and clarified.
 
 
 SOFTWARE RETRIEVAL:
 =====================
 
 The following software files are exported as part of this patch:
       
determinations calculated by the software will be automatically 
     File Name             Contents                         Transfer
 
     RMPF3_4.KID           VistA modifications              ASCII
 
     RMPF3_0P4.ZIP         Updated executables (354 KB)     BINARY
       Containing the following files:
       ROES3.exe           CPRS link to ROES web application     37 KB
       ROES3DeskTop.exe    Desktop link to ROES web application  708 KB
 
     RMPF3_0P4_DOC.ZIP     Updated documentation (1.816 MB) BINARY
approved.  Veteran eligibility requests will no longer be sent to the 
       Containing the following files:
       RMPF3_0P4IG.PDF      Installation Guide
       RMPF3_0P4SG.PDF      Security Guide
       RMPF3_0P4TM.PDF      Technical Manual
       RMPF3_0P4UM.PDF      User Manual
       RMPF3_0P4RN.PDF      Release Notes
 
 The KIDS part of the patch will be distributed in a PackMan message. It 
 and the zip file containing the executables can also be downloaded from
 the national download directory at:
Prosthetic and Sensory Aids Service (PSAS) staff for approval.  Changes 
 
     download.vista.domain.ext
 
 This site transmits the files from the first available FTP server.  
 Sites may also elect to retrieve software directly from a specific server
 as follows:
 
 OI FIELD OFFICE       FTP ADDRESS                     DIRECTORY
 
 Albany                ftp.fo-albany.domain.ext   anonymous.software
in the background calculations for Veteran eligibility are detailed in 
 Hines                 ftp.fo-hines.domain.ext    anonymous.software
 Salt Lake City        ftp.fo-slc.domain.ext      anonymous.software
 
 
 INSTALLATION INSTRUCTIONS:
 =========================
 
 Make a backup copy of the current ROES3.exe and ROES3Desktop.exe
 files (from a location where they currently are being used) to a
 backup location. Note the locations where all instances of those
the Release Notes for this patch.
 executables exist, for future maintenance.
 
 All obsolete options, routines, remote procedure calls and files from
 previous ROES versions will be removed during the installation. The list
 items being removed is listed in the ROUTINE SUMMARY SECTION of the
 build.
 
 Only ROES users need be off the system while ROES*3.0*4 is being
 installed. This patch should be installed during non-peak hours to
 minimize disruption. The total installation may take 15 minutes or more,
 
 depending on the CPRS Tools menu structure and number of ROES and
 ROES Desktop executables to update at your site. Be sure that the KIDS
 install (steps 1-9) are completed before updating the executables (steps
 10-11). The KIDS install will run in less than 2 minutes.
  
 Review your mapped set.  If the routines listed in the ROUTINE SUMMARY
 section of the build are mapped, they should be removed from the mapped
 set at this time.
 
  1.  Choose the INSTALL/CHECK MESSAGE option on the PackMan menu. 
2. For added security, the web connection has been changed from 
      Answer YES to the prompt 'Want to Continue with Load? YES//'.  This
      will load the KIDS package onto your system.
 
  2.  From the Kernel Installation and Distribution System Menu, select
      the Installation menu.
 
  3.  From this menu, you may elect to use the following options (when
      prompted for INSTALL NAME, enter RMPF*3.0*4):
      a. Backup a Transport Global - this option will create a backup
         message of any routines exported with the patch. It will not
clear http to secure http using the https protocol identifier.
         backup any changes to DD's.
      b. Compare Transport Global to Current System - this option will
         allow you to view all changes to routines that will be made 
         when the patch is installed.
      c. Verify Checksums in Transport Global - this option will allow you
         to ensure the integrity of the routines that are in the 
         Transport Global.
 
  4.  Then choose the Install Package(s) option and select RMPF*3.0*4.
 
 
  5.  When prompted "Want KIDS to INHIBIT LOGONs during the install?
      NO//", respond NO (unless otherwise indicated)
 
  6.  When prompted 'Want to DISABLE Scheduled Options, Menu Options, 
      and Protocols? YES//', respond "YES". When prompted to select the
      options you would like to place out of order, enter the following:
           
             ROES3 OPTION ACCESS          [RMPF ROES3]
 
  7.  If prompted 'Enter protocols you wish to mark as 'Out of Order': 
This patch addresses several issues that have come up at the VA Medical 
3. Adjustments were made for 64 bit terminal servers to access and 
      press <return>.
 
  8.  When prompted 'Delay Install (Minutes):  (0-60): 0//; respond '0.'
 
  9.  If you unmapped routines at the start, those SENT TO SITE
      should be returned to the mapped set once this part of the
      installation is complete.
 
 10.  Retrieve the file RMPF3_0P4.ZIP and extract files ROES3.exe and
      ROES3DeskTop.exe.
use the ROES web site.
 
 11.  All existing instances of ROES3.exe and ROES3DeskTop.exe need to
      be replaced, regardless of whether they reside on server(s) or
      individual workstation(s).
 
      To do this, copy the new executable files to those locations,
      replacing the existing version. Take care NOT to inadvertently 
      replace the ROES3.exe file with the ROES3DeskTop.exe file,
      or vice versa. When this is completed properly, the command line
      option from CPRS Tools and the desktop links to ROES should continue
 
      to work without any modifications.
 
 If additional guidance is needed for the GUI installation, please refer
 to the ROES 3 Installation Guide on the System Design and Development 
 web page at:  http://www.domain.ext/vdl. Within the Clinical section look for
 'Remote Order Entry System (ROES)'.  Under that option you will find the
 Installation Guide, Security Guide, Technical Manual and User Manual.
4. Connections from CPRS to the ROES web server will only be allowed to 
actually enter the web site if they are from a VistA production account to
prevent false Veteran information from becoming a part of the national
database.
 
5. Menu options, routines, remote procedure calls and security keys 
from prior versions of ROES that are no longer needed will be removed.
Centers since the first release of the ROES package. All issues addressed 
        Obsolete Options removed:  RMPFDE2 and RMPFDE4
        Obsolete Routines removed:  RMPFDE1,RMPFDE2,RMPFDE3 and RMPFDE4
        Obsolete Keys removed:  RMPF SUPERVISOR and RMPF SYSTEM MANAGER
        Obsolete Remote Procedures removed: RMPF ELIG MSG and RMPFELIG
 
6. Modifications for VistA and Delphi coding standards are included.
 
7. Documentation has been updated regarding the removal of the 
eligibility interactions before connecting to ROES.
 
in this patch are related to the ROES application that runs from the CPRS 
 
 Associated Remedy Tickets:
 ====================================== 
 N/A
 
 
 E3R references addressed in this patch
 ======================================
 N/A
 
Tools menu (ROES3.exe). The ROES Desktop application (ROES3Desktop.exe) 
 Test Sites
 ========
 Miami 
 Omaha
 Phoenix
 Columbia (SC)
 
 Required Builds
 =============
 
is only included for issues 2 and 3 below.
 RMPF*3.0*1
 
 
 
 This patch contains the following enhancements and problem resolutions:
 ==========================================================
 
 The ROES application requires that the user's browser have JAVA
 available and enabled in order to function.  Sun has not developed a
 64-bit version of JAVA, so on 64-bit terminal server installations the
 
 browser is not JAVA capable. This may prevent some ROES features from
 working properly. 64-bit installations also have a 32-bit browser
 which resides at a location different from the normal 32-bit location.
 That new location is:
        C:\Program Files (x86)\Internet Explorer\IEXPLORE.EXE.
 
 The ROES executables that connect to the internet application have been
 modified to check for the 32-bit Internet Explorer at that location.
 This change will not affect any current 32-bit installations because, if 
 Internet Explorer is not found at that location, ROES will look in the
 Issues addressed in this patch are:
 usual installation directories:
        C:\Program Files\Internet Explorer\IEXPLORE.EXE or
        C:\Program Files\PLUS!\Microsoft Internet\IEXPLORE.EXE
 
 On a 64-Bit installation, if the ROES application still does not work
 properly after installing the new executable, please ensure the path
 "C:\Program Files (x86)\Internet Explorer\IEXPLORE.EXE" does exist on
 the workstation.
 
 All workstations accessing the ROES application from either CPRS or the
 
 desktop need to have the RPCBroker Listener running, as in the previous
 releases of ROES. Refer to the RPCBroker Installation Guide for further
 direction, if needed. It can be retrieved from http://www.domain.ext/vdl.
 
 The following VistA routines have been modified to address new standards
 guidelines.
 
 1. RMPFRPC0 - Eligibility calculations were modified for new rules and
    categories and is now called directly from RMPFRPC1 instead of from
    remote procedure call RMPFELIG.
TRACK PACKAGE NATIONALLY YES
XPI1 NO
XPO1 NO
XPZ1 NO
SEQ# 4
BUILD COMPONENTS
  • ENTRIES:
    • RMPF ROES3
      ACTION:   SEND TO SITE
    • RMPFDE4
      ACTION:   DELETE AT SITE
    • RMPFDE2
      ACTION:   DELETE AT SITE
  • ENTRIES:
    • RMPF SUPERVISOR
      ACTION:   DELETE AT SITE
    • RMPF SYSTEM MANAGER
      ACTION:   DELETE AT SITE
  • ENTRIES:
    • RMPF ROES UPDATES (ASPS)
      ACTION:   SEND TO SITE
    • RMPF ROES UPDATES (PSAS)
      ACTION:   SEND TO SITE
  • ENTRIES:
    • RMPFDEMOG
      ACTION:   SEND TO SITE
    • RMPFELIG
      ACTION:   DELETE AT SITE
    • RMPF ELIG MSG
      ACTION:   DELETE AT SITE
  • ENTRIES:
    • RMPFDE1
      ACTION:   DELETE AT SITE
    • RMPFRPC0
      ACTION:   SEND TO SITE
      CHECKSUM:   B45495358
    • RMPFRPC1
      ACTION:   SEND TO SITE
      CHECKSUM:   B22103813
    • RMPFDE2
      ACTION:   DELETE AT SITE
    • RMPFDE3
      ACTION:   DELETE AT SITE
    • RMPFDE4
      ACTION:   DELETE AT SITE