| DESCRIPTION OF ENHANCEMENTS |
Patch PSJ*5.0*229 will correct the following issues.
schedules and schedules with a frequency greater than 1440 (dose to be
given more than once a day) calculate based on days instead of doses.
HD0000000282450 - 4 stop date calculated incorrectly?
Problem:
--------
When finishing a dose limit IV Piggyback order created in CPRS, the stop
date would not adhere to the dose limit. If there was a stop time defined
for a particular IV ROOM, the stop time would be tacked on, usually
setting the stop date past the last dose of the order. If there was no
stop time defined, the system would tack on .2359 to the stop date, which
would also usually set the stop date past the dose limit. Both of these
scenarios would cause additional doses to be given.
HD0000000347116 - 6 Edited infusion rate to remove 250 ml/hr@0 and
scheduled labels still not printing
Problem:
--------
When editing an IV order from an infusion rate with the ATZERO flag set
to an infusion rate without the ATZERO flag, the labels still don't
HD0000000339101 - PSPO# 00001478 - 1 IV order 3x/wk for 8 doses- when
print. The ATZERO flag is not being removed by an opposite edit.
HD0000000217087 - IV Time frames in question
Problem:
--------
The duration on IV orders is not calculating correctly. A duration of 23
hours stops the order after 23 hours, and a duration of 25 hours stops
the order after 25 hours; however, a duration of 24 hours stops the
order at t+1 day @ 23:59 (23:59 is set by the inpatient ward parameter as
a default time).
stop time is entered as 8, the computer calculates
for 8 days not 8 doses
Problem:
--------
Dose limit calculations are not correct when entered from the
infusion dialog in CPRS. There is no logic to calculculate day of week
|