DESCRIPTION OF ENHANCEMENTS |
-- The '%Index of Routines' option doesn't call the new version.
of the VOLUME SETS you have listed, once the installation starts.
MSM Sites - Once the install starts, KIDS will pause 5 minutes to
allow time for you to go to the other CPUs, and make them ready to
receive the patched routines.
'D ^XUP' to setup the enviroment, then 'D ^XPDCPU' to load them.
8. After installing this patch, you need to move several routines from
your productions account to the manager account:
ZIS5
ZIS6
ZISC
ZISHVXD
ZISHMSM
ZISUTL
ZOSV1VXD
ZTER
ZTER1
ZTM
NOIS DAY-0496-41713 Submanager count always low. Site and John Beaufait
ZTM5
ZTMDCL
ZTMS
ZTMS0
and in the manager account rename
Example: ZL ZISUTL ZS %ZISUTL
did a great job of researching this problem.
ZIS5 to %ZIS5
ZIS6 to %ZIS6
ZISC to %ZISC
ZISHMSM to %ZISH (MSM only)
ZISHVXD to %ZISH (VAX DSM only)
ZISUTL to %ZISUTL
ZOSV1VXD to %ZOSV1 (VAX DSM only)
ZTER to %ZTER
ZTER1 to %ZTER1
ZTM to %ZTM
ZTM5 to %ZTM5
ZTMDCL to %ZTMDCL
ZTMS to %ZTMS
ZTMS0 to %ZTMS0
9. MSM sites now move both the % and non-% new routines to the MGR
uci of the other CPU's.
9. AXP Sites, after patch has installed, rebuild your map set.
10. Restart Taskman and enable user's login.
NOIS WBP-0596-21109, SDC-0496-60862 After patch XU*8*18 if the site has
=========================================================================
error screens setup in taskman, a task getting an error would not get
its status updated. This was especially true when the error happened
setting up Network Mail tasks, Follow-up Mail would check on the status
of the task and not start new ones believing that one was starting.
E3R #8206 On VAX DSM to have TelNet links HALT from ZUVXD and not wait
Thanks to David Dahlstrand for noticing the link.
NOIS PUG-0596-51586 The new OPEN^%ZISH call wouldn't work to write a
newversion of a file. Problem was only with the VAX DSM version.
FILEMAN TEAM Problems with $$FTG^%ZISH on VAX DSM and reading records
greater than 255 char. ZISHMSM had the same problem.
NOIS DES-0795-41067 TaskMan on MSM system could see the SYSTEM SHUTDOWN
flag and would set the X-ref of the Inhibit Logon's field to prevent users
for the next user.
from login on. If the shutdown was aborted the X-ref would keep user from
login on but looking at the Volume Set file would show the Logon Inhibit
field still set to NO, this was confusing to sites. This has been fixed
by adding a new item to the set of codes System Shutdown that is set and
cleared by taskman.
NOIS IHS-0696-N0286 Site found a call to a missing TAG in %ZISH, it was
part of some code that is undocumented and the call has been removed.
NOIS DAY-0196-42100 Intermittent UNDEF in XQALDEV. One entry point didn't
have all the variables setup.
NOIS HUN-0396-20414 At VAX DSM sites running taskman from DCL the log
files could excced the VMS limit and bring Taskman to a stop. The fix
is to not record a log file.
FORUM errors. UNDEF Error at SETVAR^%ZIS1 when slecting a item from the
Local Synonym list.
BRX-0296-10688 Site needed to help identify devices to users. Site wanted
NOIS DAY-0596-40526 A syntax error at RES+1^%ZOSV1VXD
the display the Mnemonic. This is a multipule and would cause problems.
Added code to display the Device Location like the FM loopup does.
routine new checksum
XQALDEL 13827021
ZIS5 7634324
ZIS6 9961139
ZISC 8469046
ZISHMSM 5232475
ZISHVXD 6949854
ZISUTL 2111550
ZOSV1VXD 2355845
ZTER 18727059
ZTER1 5363987
ZTM 7509587
ZTM5 3649126
ZTMDCL 527042
ZTMS 4863268
ZTMS0 3205484
NOIS SDC-0596-60064 Problem was that users couldn't use ScreenMan after
ZUVXD 4856063
=========================================================================
Installation:
1. These routines are usually mapped on systems that allow mapping,
so you will need to disable mapping for the effected routines.
2. Use the 'INSTALL/CHECK MESSAGE' option on the PackMan menu. This
option will load the KIDS package onto your system.
3. The patch has now been loaded into a Transport global on your
doing 'Print a spool document' because the IO parameters didn't get reset.
system. You now need to use KIDS to install the Transport global.
On the KIDS menu, under the 'Installation' menu, use the following
options:
Print Transport Global
Compare Transport Global to Current System
Verify Checksums in Transport Global
Backup a Transport Global
5. Stop TASKMAN.
Inhibit users from login into the system. (If you install when few
user are on the system and the possibility of some CLOBER errors in
%ZIS is acceptable then users can stay on the system.)
6. On the KIDS menu, under the 'Installation' menu, use the following
options:
Install Package(s) 'XU*8.0*24'
7. VAX DSM Sites in the production account rename ZUVXD to ZU.
MSM Sites - Answer YES to the question 'Want to MOVE routines to
other CPUs?'. Enter the names of your Compute and Print server(s).
NOTE: You will see the following message: TASKMAN is not running.
You must run the routine XPDCPU in the production UCI for each
|