Print Page as PDF
DBIA1473 ICR (1473)

DBIA1473    ICR (1473)

Name Value
NUMBER 1473
IA # 1473
DATE CREATED 1996/02/09
CUSTODIAL PACKAGE AUTOMATED MED INFO EXCHANGE
CUSTODIAL ISC Albany
USAGE Private
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE DVBCTRN
NAME DBIA1473
GENERAL DESCRIPTION
Quality: Audiology and Speech Pathology Audit and
Review (QUASAR), will make calls to AMIE routines EN1^DVBCTRN and EN2^DVBCTRN.

This is done to acquire the soft link information, verify the availability of
the soft link's request, and to download information to AMIE for the purpose
of transmitting audiology C&P exam data.
STATUS Active
DURATION Till Otherwise Agreed
ID DVBCTRN
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT COMPONENT DESCRIPTION
EN1
EN1^DVBCTRN receives parameters:
#1 - Patient's DFN
#2 - Name of exam needing softlink
#3 - Softlink

returns:
Either new softlink or validity of existing softlink
EN2
EN2^DVBCTRN receives parameters:
#1 - Global or Local root of information to be loaded into AMIE
#2 - Package name calling AMIE
#3 - Softlink information
#4 - Pointer to New Person file (indicating examining physician)
#5 - Date the examination was performed (in FM format)

returns:
Indication of success/failure of download
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE ISC
QUASAR Birmingham