Print Page as PDF
VAFCDD01 ICR (3493)

VAFCDD01    ICR (3493)

Name Value
NUMBER 3493
IA # 3493
DATE CREATED 2001/12/12
CUSTODIAL PACKAGE REGISTRATION
USAGE Private
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE VAFCDD01
NAME VAFCDD01
GENERAL DESCRIPTION
Master Patient Index VistA would like to formalize the
DBIA with Registration for use of AVAFC and XMITFLAG entry points for
VAFCDD01.


AVAFC - is being used to create an A08 message when the data on the ICN has
been correlated but not updated on the site and then the site changes data but
the update is not transmitted to the other sites and the MPI.

XMITFLAG - is being used to set the REQUIRES TRANSMISSION field in the ADT/HL7
PIVOT file used in conjunction with the $$PIVNW^VAFHPIVT call to create a
Treating Facility update entry in the ADT/HL7 PIVOT file.
STATUS Active
ID VAFCDD01
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT COMPONENT DESCRIPTION VARIABLES
AVAFC
This API creates an A08 entry in the ADT/HL7 PIVOT
file.
VARIABLES TYPE VARIABLES DESCRIPTION
DFN Input
DFN is the internal entry number of the patient in
the patient file that the A08 update is to be created for.
XMITFLAG
Turn transmission flag for entry in ADT/HL7 PIVOT
file on/off.
VARIABLES TYPE VARIABLES DESCRIPTION
PIVOTPTR Input

- Pointer to entry in ADT/HL7 PIVOT file (#391.71)
- Use this parameter if the entry number is known
- Not required if using PIVOTNUM parameter
- Use of this parameter takes precedence over use the PIVOTNUM parameter
PIVOTNUM Input

PIVOT NUMBER value (field #.02) for entry in ADT/HL7 PIVOT file (#391.71)
- Use this parameter if the pivot number is known
- Not required if using PIVOTPTR parameter
TURNOFF Input
Denotes if REQUIRES TRANSMISSION field (#.08) should
be turned on (set to 'YES') or off (set to 'NO')
1 = Turns transmission off
0 = Turns transmission on (default)
SUBSCRIBING PACKAGE MASTER PATIENT INDEX VISTA