Print Page as PDF
Imaging - Consult/Request HL7 message ICR (3832)

Imaging - Consult/Request HL7 message    ICR (3832)

Name Value
NUMBER 3832
IA # 3832
DATE CREATED 2002/11/04
CUSTODIAL PACKAGE CONSULT/REQUEST TRACKING
CUSTODIAL ISC Chicago
USAGE Controlled Subscription
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE GMRCHL7
NAME Imaging - Consult/Request HL7 message
GENERAL DESCRIPTION
The Consult/Request Tracking developer has given
Imaging permission to call routine GMRCHL7 to generate HL7 message segments.
STATUS Active
ID GMRCHL7
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT COMPONENT DESCRIPTION VARIABLES
ORC
This component will build the ORC message segment in
HL7 format.
VARIABLES TYPE VARIABLES DESCRIPTION
GMRCIEN Input
This is the internal entry in file
Request\Consultation (#123).
GMRCTL Input
This is order control code for the ORC message
segment.
ORCPLCR Input
This the person who placed the order.
MAIN Input
This is the variable that controls whether to perform
a group updated.
GMRCDT Input
The date and time of the activity.
ORC Output
The return variable that contains all the input
values formatted accordingly to HL7 standards.
ZSV
The submodule for the message segment contains that
contains the service and display text for the order.
VARIABLES TYPE VARIABLES DESCRIPTION
GMRC0 Input
This is the internal entry in file
Request\Consultation (#123).
ZSV Output
The variable that has the HL7 formatted message.
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE ISC SUBSCRIBING DETAILS
IMAGING Washington/Silver Spring
Imaging is building HL7 messages to provide worklists
to the HealthCare Provider equipment interface for applications such as:
Dental, Optometry, etc. The worklist is generated from Consult/Request made to
clinics that have been defined in Imaging files as recipients of Modality
worklists.

Imaging is calling routine GMRCHL7 to build the HL7 message for segments ORC
and ZSV.