Print Page as PDF
Imaging - GMRCHL72 ICR (3833)

Imaging - GMRCHL72    ICR (3833)

Name Value
NUMBER 3833
IA # 3833
DATE CREATED 2002/11/04
CUSTODIAL PACKAGE CONSULT/REQUEST TRACKING
CUSTODIAL ISC Chicago
USAGE Controlled Subscription
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE GMRCHL72
NAME Imaging - GMRCHL72
GENERAL DESCRIPTION
The Consult/Request Tracking developer has given
Imaging permission to call routine GMRCHL72 to generate HL7 message segments.
STATUS Active
ID GMRCHL72
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT COMPONENT DESCRIPTION VARIABLES
OBR
The submodule to build the OBR message segment in HL7
format.
VARIABLES TYPE VARIABLES DESCRIPTION
GMRCIEN Input
This is the internal entry in file
Request\Consultation (#123).
RESBY Input
Internal value for person entering/interpreting
result & signing report.
GMRCACDT Input
The date/time of activity in FileMan format.
OBR Output
The return variable that contains all the input
values formatted accordingly to HL7 standards.
OBX
The submodule to build the OBX message segment in HL7
format.
VARIABLES TYPE VARIABLES DESCRIPTION
GMRCIEN Input
This is the internal entry in file
Request\Consultation (#123).
OBX Output
The variable that has the HL7 formatted message.
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE ISC SUBSCRIBING DETAILS
IMAGING Washington/Silver Spring
Imaging is building HL7 messages to provide worklists
to the HealthCare Provider equipment interface for applications such as:
Dental, Optometry, etc. The worklist is generated from Consult/Request made to
clinics that have been defined in Imaging files as recipients of Modality
worklists.

Imaging is calling routine GMRCHL72 to build the HL7 message for segments OBR
and OBX.