GENERAL DESCRIPTION |
Add VistALink option XOBV LISTENER STARTUP to the
OPTIONS SCHEDULING file (#19.2) during the post-installation phase of the
VistALink package. Also, perform a lookup on the "B" cross reference of the
new entry, and as part of the post-installation display this record's zero
node.
Revision History:
- 2/28/25, effective with DVBA*2.7*253, added new OTHER PARAMETERS (#10)
multiple, and the VARIABLE NAME (#.01) and VALUE (#1) fields, where field
content can be added, modified or removed when the package owns the namespaced
entry being modified.
|
GLOBAL REFERENCE |
GLOBAL REFERENCE |
FIELD NUMBER |
DIC(19.2, |
FIELD NUMBER |
ACCESS |
FIELD NAME |
LOCATION |
.01 |
Both R/W w/Fileman |
NAME |
0;1 |
9 |
Both R/W w/Fileman |
SPECIAL QUEUEING |
0;9 |
|
DIC(19.2,DA(1),2,0) |
FIELD NUMBER |
ACCESS |
FIELD DESCRIPTION |
FIELD NAME |
LOCATION |
10 |
Both R/W w/Fileman |
This multiple holds name-value pairs that are setup
before the option is run.
|
OTHER PARAMETERS |
2;0 |
.01 |
Both R/W w/Fileman |
Read, write and remove name-value pairs
|
VARIABLE NAME |
0;1 |
1 |
Both R/W w/Fileman |
Read, write and remove name-value pairs
|
VALUE |
0;2 |
|
|